EUVIMEDEUVIMED entdecken
Kohortenstudie

Endoscopic Ultrasound Point Shear-Wave Elastography Intra-Observer Reproducibility: A 120-Patient Prospective Cohort Study

B Ghita-Adrian, B Miutescu, E Gadour, A Brasovan, C Burciu, I Ratiu, T Moga, A M Ghiuchici, A Popescu

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S80-S81

DOI: 10.1055/s-0046-1820769 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von B Ghita-Adrian und 8 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Echo-endoscopic point shear-wave elastography (EUS-pSWE) bypasses subcutaneous adiposity and may provide weight-agnostic liver-stiffness assessment; however, reproducibility data in real-world endoscopy practice remain limited. We aimed to quantify intra-observer reproducibility under routine EUS conditions, benchmark stiffness values against vibration-controlled transient elastography (VCTE), and evaluate clinical and technical modifiers of measurement precision.

Methods

In this single-centre prospective cohort (April 2024–February 2025), 120 consecutive adults undergoing diagnostic EUS were enrolled. Each hepatic lobe underwent two sets of five EUS-pSWE acquisitions without scope repositioning. Intra-observer reproducibility was assessed using ICC(3,1), with ICC≥0.80 considered acceptable. Same-day VCTE served as an external comparator. The influence of BMI, underlying liver-disease etiology, and operator experience on acquisition validity and reliability was explored.

Results

Forty-six participants were obese (BMI≥30 kg/m²). Overall EUS-pSWE acquisition validity was 66.7%, increasing to 87.9% in obese versus 55.2% in non-obese individuals (p

Zitieren

APA

Ghita-Adrian, B., Miutescu, B., Gadour, E., Brasovan, A., Burciu, C., Ratiu, I., Moga, T., Ghiuchici, A. M., & Popescu, A. (2026). Endoscopic Ultrasound Point Shear-Wave Elastography Intra-Observer Reproducibility: A 120-Patient Prospective Cohort Study. Endoscopy, 58(S 03 S 03), S80-S81. https://doi.org/10.1055/s-0046-1820769

Vancouver

Ghita-Adrian B, Miutescu B, Gadour E, Brasovan A, Burciu C, Ratiu I, et al. Endoscopic Ultrasound Point Shear-Wave Elastography Intra-Observer Reproducibility: A 120-Patient Prospective Cohort Study. Endoscopy. 2026;58(S 03 S 03):S80-S81. doi:10.1055/s-0046-1820769

BibTeX
@article{GhitaAdrian2026,
  author = {Ghita-Adrian, B and Miutescu, B and Gadour, E and Brasovan, A and Burciu, C and Ratiu, I and Moga, T and Ghiuchici, A M and Popescu, A},
  title = {Endoscopic Ultrasound Point Shear-Wave Elastography Intra-Observer Reproducibility: A 120-Patient Prospective Cohort Study},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S80--S81},
  doi = {10.1055/s-0046-1820769}
}
Kostenlos starten →