EUVIMEDEUVIMED entdecken
Crossref

Automated Lewis Score Binary Classification From Frame Probabilities

S Kurant, S Shai, B Yiftach, F Orel, A Talan Asher, S Ben-Horin, E Klang, U Kopylov

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S64-S65

DOI: 10.1055/s-0046-1820741 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von S Kurant und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Problem to solve The Lewis Score (LS) is an established capsule endoscopy (CE) index for grading small-bowel inflammation in Crohn’s disease (CD) and guiding therapy decisions. However, deriving an LS requires full CE video review, making it time-consuming and prone to inter-observer variability. As the number of CE procedures grows, manual scoring has become increasingly impractical. While most AI models operate at the frame level, clinical interpretation depends on the study level. Bridging this gap requires automated tools that provide both accuracy and interpretability at clinically meaningful LS thresholds. Innovation We developed a video-level classification framework that transforms frame-wise probabilities into interpretable temporal features, facilitating automated LS classification across severity thresholds. A fine-tuned convolutional network produced frame probabilities for four categories: normal mucosa, ulcer, stricture, and uninterpretable frames. From these probabilities, we derived 42 summary features for each study, including the longest contiguous ulcer sequence, the duration above high-probability thresholds, and the distribution of ulcer and stricture signals throughout bowel segments [ 1 ] [ 2 ] [ 3 ]. These features served as inputs to logistic regression and a multilayer perceptron (MLP). In parallel, a 1D convolutional neural network (CNN) with attention operated directly on the sequence of per-frame probabilities. We evaluated how accurately these models assigned videos above vs below predefined LS thresholds ([ Table 1 ]). The dataset included 1,135 CE videos analyzed using five-fold, patient-grouped cross-validation to prevent patient leakage and ensure robust generalization. Models were trained and tested across LS thresholds of≥135 (mild),≥790 (moderate), and≥2000 (severe).

Results

Across thresholds, models achieved substantial and consistent discrimination. Average AUROC reached 0.81 (95% CI 0.79–0.83) at LS≥135, 0.89 (0.89–0.90) at LS≥790, and 0.88 (0.82–0.91) at LS≥2000. Sensitivity and specificity were well balanced (≈0.7–0.8 and 0.82–0.85, respectively). CNN attention maps consistently highlighted the distal third of the small bowel—where Crohn’s pathology typically peaks—while logistic regression and MLP importance analyses emphasized ulcer burden and distal involvement. The convergence between spatial attention and feature-level importance provides explainability and supports the clinical plausibility of the approach. These results show that video-level LS classification can be achieved without direct manual annotation of the entire video, using only frame-wise probabilities as input.

Conclusions

Frame-wise probabilistic outputs enabled video-level models to distinguish between various studies across multiple LS thresholds effectively. This framework also provided interpretable, threshold-specific feature profiles offering insights into relevant characteristics at different LS thresholds that are consistent with expected patterns. These results indicate promise for triage support; however, external, multi-centre validation, calibration, and prospective assessment within clinical workflows are necessary. This work was performed with a generous support of the Leona M. and Harvey B. Helmsley Foundation. Table 1 Performance Metrics by Model and Threshold Model AUROC (95% CI) Sensitivity (95% CI) Specificity (95% CI) LS≥135 Logistic Regression 0.832 (0.810–0.854) 0.701 (0.679–0.723) 0.895 (0.857–0.932) MLP 0.793 (0.767–0.817) 0.705 (0.684–0.728) 0.745 (0.692–0.796) CNN (1D+attention) 0.806 (0.806–0.806) 0.709 (0.709–0.709) 0.819 (0.819–0.819) LS≥790 Logistic Regression 0.897 (0.880–0.915) 0.787 (0.750–0.825) 0.856 (0.838–0.873) MLP 0.889 (0.871–0.906) 0.810 (0.776–0.846) 0.827 (0.808–0.846) CNN (1D+attention) 0.888 (0.869–0.907) 0.726 (0.686–0.771) 0.876 (0.860–0.893) LS≥2000 Logistic Regression 0.907 (0.866–0.956) 0.851 (0.774–0.929) 0.876 (0.861–0.891) MLP 0.908 (0.872–0.947) 0.851 (0.774–0.931) 0.859 (0.843–0.876) CNN (1D+attention) 0.818 (0.818–0.818) 0.809 (0.809–0.809) 0.798 (0.798–0.798) Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Kurant, S., Shai, S., Yiftach, B., Orel, F., Asher, A. T., Ben-Horin, S., Klang, E., & Kopylov, U. (2026). Automated Lewis Score Binary Classification From Frame Probabilities. Endoscopy, 58(S 03 S 03), S64-S65. https://doi.org/10.1055/s-0046-1820741

Vancouver

Kurant S, Shai S, Yiftach B, Orel F, Asher AT, Ben-Horin S, et al. Automated Lewis Score Binary Classification From Frame Probabilities. Endoscopy. 2026;58(S 03 S 03):S64-S65. doi:10.1055/s-0046-1820741

BibTeX
@article{Kurant2026,
  author = {Kurant, S and Shai, S and Yiftach, B and Orel, F and Asher, A Talan and Ben-Horin, S and Klang, E and Kopylov, U},
  title = {Automated Lewis Score Binary Classification From Frame Probabilities},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S64--S65},
  doi = {10.1055/s-0046-1820741}
}
Kostenlos starten →