Evaluation of a real-time Computer-aided Detection and Diagnosis system for Barrett’s neoplasia during live endoscopic procedures: A multicenter prospective study

R van Eijck van Heslinga, F Slooter, M Jong, K Kusters, T Jaspers, T Boers, L Duits, R Pouw, B Weusten, L Alvarez Herrero, A Alkhalaf, P De With und 3 weitere

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S54

DOI: 10.1055/s-0046-1820724 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von R van Eijck van Heslinga und 14 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Computer-aided detection (CADe) systems have the potential to improve endoscopic detection of early neoplasia in Barrett’s esophagus (BE). Additionally, computer-aided diagnosis (CADx) systems may assist in subsequent characterization of detected lesions. We aimed to test a recently developed combined CADe/CADx system for BE neoplasia during live endoscopic procedures [ 1 ] [ 2 ].

Methods

CADe and CADx were evaluated during endoscopic procedures of BE patients undergoing regular surveillance or endoscopic work-up for low-grade dysplasia (LGD), high-grade dysplasia (HGD), or esophageal adenocarcinoma (EAC) in 3 tertiary centers. All procedures were performed by expert endoscopists with over 5 years’ experience with diagnosis and treatment of early BE neoplasia. First, ground truth for CADe (i.e. the presence or absence of a visible lesion requiring targeted biopsy) was established by the expert endoscopist using white light endoscopy (WLE). If a visible lesion was identified, it was subsequently characterized using narrow band imaging (NBI) as either normal mucosa or suspicious of neoplasia, serving as ground truth for CADx. Then, the CADe/CADx study protocol was initiated, which involved endoscopic examination in 2cm intervals throughout the BE segment, with real-time support of CADe. Any lesion identified by CADe was then evaluated by CADx after which targeted biopsies were obtained or the lesion was resected. Random biopsies were obtained according to standard protocol. Primary outcomes were the stand-alone sensitivity of CADe, and the mean number of false-positive CADe detections per patient. Secondary outcomes were the stand-alone sensitivity of CADx for characterizing CADe-detected lesions, and the reduction of CADe false-positive detections by CADx.

Results

In total, 182 patients were enrolled in the study. In 74 patients, a visible lesion was found in WLE by the expert endoscopist. The CADe system detected 67/74 of these lesions, resulting in a sensitivity of 91%. Of all detected lesions, histopathological examination confirmed neoplasia in 63% (i.e. EAC, HGD, or LGD). Of the 7 lesions missed by CADe, 5 were neoplastic (2x EAC, 1x HGD, 2x LGD), and 2 did not contain neoplasia. In 108 procedures, no visible lesion was identified by the expert endoscopist in WLE. In these procedures, CADe generated 69 false-positive detections in total, resulting in 0.63 false-positives per procedure. Of all 67 CADe-detected lesions, 58 were considered suspicious for neoplasia during NBI assessment by the expert endoscopist. All 58 lesions were correctly classified as neoplastic by CADx, resulting in a sensitivity of 100%. Furthermore, CADx discarded 35 of the 69 CADe false-positive detections, reducing the mean number of false positives per procedure from 0.63 to 0.31. Extrapolated to clinical practice, this would result in one additional targeted biopsy every 3 patients.

Conclusions

This is the largest study to date to evaluate a combined CADe/CADx system for real-time detection of BE neoplasia. The CADe system demonstrated a per-patient sensitivity of 91% for all visible lesions identified by the expert endoscopist, with an acceptable number of false positive detections. The CADx system showed potential to further reduce false-positives, without discarding any prior CADe true positive detections. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Heslinga, R. V. E. V., Slooter, F., Jong, M., Kusters, K., Jaspers, T., Boers, T., Duits, L., Pouw, R., Weusten, B., Herrero, L. A., Alkhalaf, A., With, P. D., Sommen, F. V. D., Bergman, J., & Groof, J. D. (2026). Evaluation of a real-time Computer-aided Detection and Diagnosis system for Barrett’s neoplasia during live endoscopic procedures: A multicenter prospective study. Endoscopy, 58(S 03 S 03), S54. https://doi.org/10.1055/s-0046-1820724

Vancouver

Heslinga RVEV, Slooter F, Jong M, Kusters K, Jaspers T, Boers T, et al. Evaluation of a real-time Computer-aided Detection and Diagnosis system for Barrett’s neoplasia during live endoscopic procedures: A multicenter prospective study. Endoscopy. 2026;58(S 03 S 03):S54. doi:10.1055/s-0046-1820724

BibTeX
@article{Heslinga2026,
  author = {Heslinga, R van Eijck van and Slooter, F and Jong, M and Kusters, K and Jaspers, T and Boers, T and Duits, L and Pouw, R and Weusten, B and Herrero, L Alvarez and Alkhalaf, A and With, P De and Sommen, F Van Der and Bergman, J and Groof, J De},
  title = {Evaluation of a real-time Computer-aided Detection and Diagnosis system for Barrett’s neoplasia during live endoscopic procedures: A multicenter prospective study},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S54},
  doi = {10.1055/s-0046-1820724}
}
Kostenlos starten →