EUVIMEDEUVIMED entdecken
Crossref

Ingenuous Ruler-Guided Technique to Achieve Accurate Angles in Z-Plasty Design: A Reliability and Feasibility Study

Naveen Narayan

Indian Journal of Plastic Surgery · 28.05.2026

DOI: 10.1055/s-0046-1819650 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Plastic Surgery, erschienen am 28.05.2026. Verfasst von Naveen Narayan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate angle construction is fundamental to successful Z-plasty. Conventional tools such as protractors are often impractical in operative settings due to sterility issues, difficulty on curved surfaces, and workflow disruption. We developed a simple ruler-based technique using multiplication factors (0.25X, 0.5X, 0.7X, 0.9X, 1.0X) to construct standard angles without specialized instruments.

Objective

The aim of the study is to validate a simplified ruler-guided multiplication-factor technique for constructing Z-plasty angles without angle-measuring instruments and to assess its accuracy, reliability, and clinical feasibility. Materials and Methods This prospective two-phase observational study included (Phase 1: 50 tracings per angle) derivation and reproducibility testing of multiplication factors for standard Z-plasty angles by five surgeons and (Phase 2) clinical validation in 32 consecutive patients undergoing Z-plasty. Ruler-guided designs were compared with sterile protractor measurements. Primary outcomes were agreement assessed by intraclass correlation coefficient (ICC) and Bland–Altman analysis. Secondary outcomes included plotting time, surgeon-reported usability, and early postoperative complications.

Results

Multiplication factors demonstrated high reproducibility (SD ≤0.03) with minimal interobserver variability. Clinical validation showed excellent agreement between ruler-guided and protractor-based measurements (ICC 0.94; 95% CI 0.90–0.97). Bland–Altman analysis demonstrated a mean bias of 0.8° with limits of agreement from −3.1° to +4.7°. Plotting time was significantly shorter using the ruler-guided technique (22 ± 6 second vs. 65 ± 12 second p

Zitieren

APA

Narayan, N. (2026). Ingenuous Ruler-Guided Technique to Achieve Accurate Angles in Z-Plasty Design: A Reliability and Feasibility Study. Indian Journal of Plastic Surgery. https://doi.org/10.1055/s-0046-1819650

Vancouver

Narayan N. Ingenuous Ruler-Guided Technique to Achieve Accurate Angles in Z-Plasty Design: A Reliability and Feasibility Study. Indian Journal of Plastic Surgery. 2026. doi:10.1055/s-0046-1819650

BibTeX
@article{Narayan2026,
  author = {Narayan, Naveen},
  title = {Ingenuous Ruler-Guided Technique to Achieve Accurate Angles in Z-Plasty Design: A Reliability and Feasibility Study},
  journal = {Indian Journal of Plastic Surgery},
  year = {2026},
  doi = {10.1055/s-0046-1819650}
}
Kostenlos starten →