Abstract (Originalsprache)

Background

The endoscopic transorbital approach (ETOA) provides minimally invasive access to the skull base but requires orbital retraction across key zones to establish a surgical corridor. Retraction is essential for exposure but entails risks of orbital morbidity, such as optic neuropathy, muscle dysfunction, and venous congestion. While ophthalmologic studies describe intraorbital pressure thresholds for ischemia, their relevance to ETOA is uncertain. Quantitative data on retraction forces and pressures remain limited, and the biomechanical behavior of specific orbital zones during surgical maneuvers has not been systematically assessed.

Objective

To quantify orbital retraction force and intraorbital pressure during key ETOA steps and identify location-specific biomechanical responses.

Methods

Three human cadaveric specimens were studied. Retraction force (N) and intraorbital pressure (mmHg) were recorded at the optic canal (OC), superior orbital fissure (SOF), and inferior orbital fissure (IOF) under three conditions: baseline, after meningoorbital band (MOB) release, and after MOB release plus superior orbital rim (SOR) craniotomy. Stepwise comparisons, effect sizes, and correlation analyses were performed.

Results

MOB release reduced force most at the OC (−0.78 N, −48.4%, p = 0.004), with smaller decreases at the SOF (−0.63 N, −32.9%) and IOF (−0.39 N, −21.8%). SOR craniotomy produced minimal additional change (≤0.03 N). For pressure, the SOF demonstrated the strongest response, with decreases of −26.1 mm Hg (−78.6%, p = 0.011) after MOB and −23.3 mm Hg (−69.3%, p = 0.015) following additional SOR craniotomy. OC (−7.1 mm Hg, −50.1%) and IOF (−7.4 mm Hg, −36.8%) showed smaller, nonsignificant changes. Force and pressure were modestly correlated overall (r = 0.39), strongest at the SOF (r = 0.67). Fig. 1 Intraocular pressure trajectories. Fig. 2 Retraction force trajectories.

Conclusion

Orbital retraction during ETOA shows location-specific biomechanical patterns: the OC is predominantly force-sensitive, while the SOF is pressure-sensitive. MOB release emerges as the key maneuver altering orbital mechanics, whereas SOR craniotomy contributes little additional effect. These findings provide a quantitative framework for orbital biomechanics in transorbital surgery. Publication History Article published online: 27 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Odeibat, Y., Gago, G., Monsalve, M., Comeau, M., & Champagne, P. (2026). Biomechanical Assessment of Orbital Retraction in the Endoscopic Transorbital Approach: A Cadaveric Study. Journal of Neurological Surgery Part B: Skull Base, 87(S 01 S 01), S1-S548. https://doi.org/10.1055/s-0046-1818865

Vancouver

Odeibat Y, Gago G, Monsalve M, Comeau M, Champagne P. Biomechanical Assessment of Orbital Retraction in the Endoscopic Transorbital Approach: A Cadaveric Study. Journal of Neurological Surgery Part B: Skull Base. 2026;87(S 01 S 01):S1-S548. doi:10.1055/s-0046-1818865

BibTeX
@article{Odeibat2026,
  author = {Odeibat, Yousef and Gago, Guilherme and Monsalve, Martin and Comeau, Marc-Olivier and Champagne, Pierre-Olivier},
  title = {Biomechanical Assessment of Orbital Retraction in the Endoscopic Transorbital Approach: A Cadaveric Study},
  journal = {Journal of Neurological Surgery Part B: Skull Base},
  year = {2026},
  volume = {87},
  number = {S 01 S 01},
  pages = {S1--S548},
  doi = {10.1055/s-0046-1818865}
}
Kostenlos starten →