TRANSLATIONAL DEVELOPMENT AND FIRST-IN HUMAN PET IMAGING OF 68GA-LABELLED SIDEROPHORES FOR SPECIFIC DETECTION OF BACTERIAL INFECTIONS
Nuklearmedizin - NuclearMedicine · 01.04.2026 · 65 (02) · 163
DOI: 10.1055/s-0046-1818341 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2026. Verfasst von D Weiberg und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Ziel/Aim: In complex clinical situations such as fever of unknown origin or suspected infection of implants, PET can help to localize and identify infectious foci. [ 18 F]FDG is often used, but cannot differentiate between infection and sterile inflammation. Our novel siderophore-based radiotracer, [ 68 Ga]Ga-SIGA, targets the bacteria-specific iron metabolism, and is thereby a promising tool for the specific, non-invasive detection of bacterial pathogens. In preclinical evaluation, [ 68 Ga]Ga-SIGA showed specific uptake in Gram positive and negative bacteria and in a majority of the ESKAPE(E) bacteria in vitro . Furthermore, in mouse models, [ 68 Ga]Ga-SIGA detected bacterial infections in vivo and allowed for differentiation from sterile inflammation [ 1 ]. Across a panel of artificial siderophores, [ 68 Ga]Ga-SIGA emerged as the most promising compound for further translational development. Methodik/Methods: GMP compliant production as well as comprehensive quality control according to Ph. Eur. and GMP were pursued. Our efforts showed that [ 68 Ga]Ga-SIGA can be produced via an automated, reliable and GMP compliant process. All quality control measurements were within the Ph. Eur. acceptance criteria. Clinical application was conducted in 10 patients with suspected infection of a left ventricular assist device (LVAD) system, where routine [ 18 F]FDG PET/CT scans to identify severity of immune activation were amended by [ 68 Ga]Ga-SIGA in order to identify presence of bacterial pathogens. Patients were dynamically scanned with [ 68 Ga]Ga-SIGA for 60 min, followed by a late static scan at 90 min p.i. Ergebnisse/Results: These first-in-human PET/CT studies visualized [ 68 Ga]Ga-SIGA foci in patients with proven bacterial infection of their LVAD system. Of note, [ 68 Ga]Ga-SIGA showed slow pharmacokinetics with a long circulation time of up to 60 min, but almost no background except for renal elimination. Infectious foci showed specific uptake versus background (infection foci; SUVmax: 5.15±0.75 vs. bloodpool; SUVmean: 2.01±0.41). Schlussfolgerungen/Conclusion: These preliminary data support further clinical investigations using [ 68 Ga]Ga-SIGA. Imaging studies using highly sensitive next-generation long axial field of view PET/CT may contribute to further improvement of study quality. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Weiberg, D., Al-Bazaz, S., Hilker, S., Brönstrup, M., Bengel, F., & Ross, T. (2026). TRANSLATIONAL DEVELOPMENT AND FIRST-IN HUMAN PET IMAGING OF 68GA-LABELLED SIDEROPHORES FOR SPECIFIC DETECTION OF BACTERIAL INFECTIONS. Nuklearmedizin - NuclearMedicine, 65(02), 163. https://doi.org/10.1055/s-0046-1818341
Vancouver
Weiberg D, Al-Bazaz S, Hilker S, Brönstrup M, Bengel F, Ross T. TRANSLATIONAL DEVELOPMENT AND FIRST-IN HUMAN PET IMAGING OF 68GA-LABELLED SIDEROPHORES FOR SPECIFIC DETECTION OF BACTERIAL INFECTIONS. Nuklearmedizin - NuclearMedicine. 2026;65(02):163. doi:10.1055/s-0046-1818341
BibTeX
@article{Weiberg2026,
author = {Weiberg, D and Al-Bazaz, S and Hilker, S and Brönstrup, M and Bengel, F and Ross, T},
title = {TRANSLATIONAL DEVELOPMENT AND FIRST-IN HUMAN PET IMAGING OF 68GA-LABELLED SIDEROPHORES FOR SPECIFIC DETECTION OF BACTERIAL INFECTIONS},
journal = {Nuklearmedizin - NuclearMedicine},
year = {2026},
volume = {65},
number = {02},
pages = {163},
doi = {10.1055/s-0046-1818341}
}
EUVIMED