Release Criteria for Therapies with 177Lu-labeled Radiopharmaceuticals
Nuklearmedizin - NuclearMedicine · 01.04.2026 · 65 (02) · 142
DOI: 10.1055/s-0046-1818281 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2026. Verfasst von E Rathsmann.
Abstract (Originalsprache)
Ziel/Aim: In recent years, the number of patients treated with 177 Lu-labeled radiopharmaceuticals was on the increase. This trend is set to continue. However, the European Commission’s final report on the SAMIRA study criticises the lack of uniform release criteria. This work aims to investigate practical release criteria for 177 Lu-therapies and to compare them with each other. Methodik/Methods: Whole-body dose rates of 17 patients with mCRPC (mean age (70±6) years) treated with 177 Lu-PSMA-617 (Pluvicto TM , mean activity (7713±134) MBq) were measured at a distance of 1 m from the patient’s surface from the anterior and posterior view while standing at 9 time points p.i. The dose rate was calculated as the geometric mean. The data were fitted by a mono-exponential and a bi-exponential curve using R. The AIC was calculated for both models. The radiation dose to the public was calculated based on typical daily exposure situations for people who are most affected based on an equation derived from the bi-exponential model. Common release criteria were compared with each other in terms of radiation exposure. Ergebnisse/Results: The dependence of the coefficient of variation on the measurement time indicates that the measured dose rate is superior to a fixed discharge time as a release criterion. The calculated values of the AIC illustrate that the bi-exponential model is superior to the mono-exponential model in describing the decay behaviour of the dose rate. Therefore, the mono-exponential model underestimates the radiation exposure to the public. For the calculation of the radiation dose to the public, the use of individual half-lives after 48 h is sufficient. For a conservative estimation of the radiation dose to the public, the maximum number of cycles per year must be considered. Schlussfolgerungen/Conclusion: If a patient is discharged with a dose rate greater than 2.9 µSvh -1 , this leads to a significant radiation exposure in the event of patient non-compliance with contact restrictions. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Rathsmann, E. (2026). Release Criteria for Therapies with 177Lu-labeled Radiopharmaceuticals. Nuklearmedizin - NuclearMedicine, 65(02), 142. https://doi.org/10.1055/s-0046-1818281
Vancouver
Rathsmann E. Release Criteria for Therapies with 177Lu-labeled Radiopharmaceuticals. Nuklearmedizin - NuclearMedicine. 2026;65(02):142. doi:10.1055/s-0046-1818281
BibTeX
@article{Rathsmann2026,
author = {Rathsmann, E},
title = {Release Criteria for Therapies with 177Lu-labeled Radiopharmaceuticals},
journal = {Nuklearmedizin - NuclearMedicine},
year = {2026},
volume = {65},
number = {02},
pages = {142},
doi = {10.1055/s-0046-1818281}
}
EUVIMED