EUVIMEDEUVIMED entdecken
Crossref

Correlation of Peak Oxygen Uptake with a Standardized Stair-Climbing Test in Children and Adolescents

A. Becker, M. Jaros, F. Morassutti Vitale, S. Manai, J. Birnbaum, K. Beil, N. Haas, M. Schrader

The Thoracic and Cardiovascular Surgeon · 2026-01 · 74 (S 02) · S71-S98

DOI: 10.1055/s-0046-1817422 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, online erschienen am 17.02.2026. Verfasst von A. Becker und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

All articles of this category (opens in new window)

Background

Cardiorespiratory fitness (CRF) is a key marker for cardiovascular health. The gold standard for measuring cardiorespiratory fitness is the maximal oxygen uptake measured by cardiopulmonary exercise testing (CPET). This method is time-consuming, costly, and requires a lot of equipment. Therefore, it is not available in every facility. A standardized stair-climbing-test (SCT) was recently developed and showed a strong correlation with the maximal oxygen uptake in a pilot study with 28 healthy adult participants. Its feasibility and safety were confirmed in a cohort of 827 children and adolescents. Based on these results, we wanted to evaluate the correlation of the stair-climbing test and the peak oxygen uptake in a larger pediatric cohort.

Methods

Peak oxygen uptake (VO 2 peak; absolute and relative to body weight) was measured in 110 children and adolescents (13.1 ± 2.3 years; 54.5% male) by standard cardiopulmonary exercise testing, and at the same visit, each participant additionally performed the standardized stair-climbing test (SCT). For the SCT, the required time to climb a minimum of 12 m height and four flights of stairs was normalized to 12 m (tSCT12m), and the stair-climbing-test-index (SCT-index = (body weight× staircase height)/SCT-time) was calculated. Associations with peak oxygen uptake were examined using Pearson correlation and linear regression analyses.

Results

The SCT-Index showed a strong correlation with absolute VO 2 peak (mL/minute; r = 0.884; 95% CI: 0.834–0.919; p < 0.001). Linear regression analysis confirmed the SCT-Index significantly predicted VO 2 peak ( p < 0.001). For the normalized 12 m time, a moderate negative correlation with relative VO 2 peak (mL/minute/kg) was found ( r = −0.418; 95% CI: −0.561 to −0.250; p < 0.001). Linear regression analysis showed that the 12 m time was a significant but weaker predictor of VO 2 peak ( p < 0.001).

Conclusion

The SCT-Index strongly reflects absolute VO 2 peak (mL/minute), while 12 m time shows a weaker but still significant correlation with relative VO 2 peak (mL/minute/kg). The stair-climbing test, therefore, offers a practical, safe, and cost-effective tool for estimating cardiorespiratory fitness in children and adolescents. Publication History Article published online: 17 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Becker, A., Jaros, M., Vitale, F. M., Manai, S., Birnbaum, J., Beil, K., Haas, N., & Schrader, M. (2026). Correlation of Peak Oxygen Uptake with a Standardized Stair-Climbing Test in Children and Adolescents. The Thoracic and Cardiovascular Surgeon, 74(S 02), S71-S98. https://doi.org/10.1055/s-0046-1817422

Vancouver

Becker A, Jaros M, Vitale FM, Manai S, Birnbaum J, Beil K, et al. Correlation of Peak Oxygen Uptake with a Standardized Stair-Climbing Test in Children and Adolescents. The Thoracic and Cardiovascular Surgeon. 2026;74(S 02):S71-S98. doi:10.1055/s-0046-1817422

BibTeX
@article{Becker2026,
  author = {Becker, A. and Jaros, M. and Vitale, F. Morassutti and Manai, S. and Birnbaum, J. and Beil, K. and Haas, N. and Schrader, M.},
  title = {Correlation of Peak Oxygen Uptake with a Standardized Stair-Climbing Test in Children and Adolescents},
  journal = {The Thoracic and Cardiovascular Surgeon},
  year = {2026},
  volume = {74},
  number = {S 02},
  pages = {S71--S98},
  doi = {10.1055/s-0046-1817422}
}
Kostenlos starten →