EUVIMEDEUVIMED entdecken
Crossref

Computed Tomography-Based Chordae and Anterior Mitral Leaflet Measurement to Aid Selection of Loop Length and Ring Size in Minimally Invasive Mitral Valve Repair

M. Silaschi, V. Ciobanu, P. Lashgari, J. Kruse, M. Hamiko, S. Salamate, S. Zimmer, D. Kütting, F. Bakhtiary

The Thoracic and Cardiovascular Surgeon · 01.01.2026 · 74 (S 01 S 01) · S1-S70

DOI: 10.1055/s-0046-1817347 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, erschienen am 01.01.2026. Verfasst von M. Silaschi und 8 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

All articles of this category (opens in new window)

Background

Correct chordae length and anterior mitral leaflet size measurement during minimally invasive mitral valve repair (MIS-MVR) remain challenging if performed intraoperatively. The objective was to create a protocol for loop length and anterior mitral leaflet size prediction according to preoperative computed tomography scan.

Methods

ECG-gated, contrast-enhanced CT with 0.6 mm slice thickness from neck to groin has been proposed as a standard preoperative diagnostic tool for MIS-MVR in various publications. Time-delayed CT spirals allow for analysis during certain time points in the cardiac cycle. We used dedicated software for further analyses of the obtained images in our MIS-MVR cases. In Systole (20% Cycle Time), the distance of papillary muscle ends from the point of coaptation is measured. In diastole (80% Cycle Time), the length of the anterior mitral leaflet is also measured from the annular plane to the tip of the leaflet. Ring Size and Loop length were also measured intraoperatively and chosen accordingly. Loops are available from 12 to 26 mm. We performed a retrospective analysis and compared the results to the actual chosen intraoperative loops and ring sizes.

Results

We performed CT analysis according to this protocol in 34 patients undergoing MIS-MVR for primary mitral regurgitation. In all patients, diastolic measurements were possible. In 17 patients, time-delayed spiral allowed for the systolic measurement of loop length. Mean predicted chordae length was 21.5 ± 5.2 mm from the anterior papillary muscle and 21.7 ± 3.3 mm from the posterior papillary muscle ends, respectively; mean actual loop length used was 20.1 ± 1.5 mm. The majority of chordae replacement was performed in the P2 segment (91.2%). Chordae length measurement within the margin of error (2 mm) aligned with the actually used loop length in 76.5% (14/17). The length of the anterior mitral leaflet could be estimated in 24 patients and was 35.8 ± 3.0 mm. The mean ring size used was 35.3 ± 2.1 mm. The mitral valve was successfully repaired in 100%, cross-clamp time was 55.0 ± 31.9 minutes. Residual MR was none/mild in 97.1% (33/34). Mitral valve gradient at discharge was 3.6 ± 1.4 mmHg. All patients survived and were discharged successfully.

Conclusion

Preoperative CT-based measurement of anterior mitral leaflet size and chordae length using dedicated software is a promising, innovative tool for improved preparation in MIS-MVR. This technique may further ease operative steps and shorten crossclamp times. Publication History Article published online: 17 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Silaschi, M., Ciobanu, V., Lashgari, P., Kruse, J., Hamiko, M., Salamate, S., Zimmer, S., Kütting, D., & Bakhtiary, F. (2026). Computed Tomography-Based Chordae and Anterior Mitral Leaflet Measurement to Aid Selection of Loop Length and Ring Size in Minimally Invasive Mitral Valve Repair. The Thoracic and Cardiovascular Surgeon, 74(S 01 S 01), S1-S70. https://doi.org/10.1055/s-0046-1817347

Vancouver

Silaschi M, Ciobanu V, Lashgari P, Kruse J, Hamiko M, Salamate S, et al. Computed Tomography-Based Chordae and Anterior Mitral Leaflet Measurement to Aid Selection of Loop Length and Ring Size in Minimally Invasive Mitral Valve Repair. The Thoracic and Cardiovascular Surgeon. 2026;74(S 01 S 01):S1-S70. doi:10.1055/s-0046-1817347

BibTeX
@article{Silaschi2026,
  author = {Silaschi, M. and Ciobanu, V. and Lashgari, P. and Kruse, J. and Hamiko, M. and Salamate, S. and Zimmer, S. and Kütting, D. and Bakhtiary, F.},
  title = {Computed Tomography-Based Chordae and Anterior Mitral Leaflet Measurement to Aid Selection of Loop Length and Ring Size in Minimally Invasive Mitral Valve Repair},
  journal = {The Thoracic and Cardiovascular Surgeon},
  year = {2026},
  volume = {74},
  number = {S 01 S 01},
  pages = {S1--S70},
  doi = {10.1055/s-0046-1817347}
}
Kostenlos starten →