EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparative Dosimetric Analysis of System Displayed versus Calculated Entrance Skin Dose in Routine Radiographic Imaging

Abhishek Kumar, Shuchi Bhatt, Atul Mishra, A.K. Srivastava

Indian Journal of Radiology and Imaging · 24.02.2026

DOI: 10.1055/s-0046-1817157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Radiology and Imaging, erschienen am 24.02.2026. Verfasst von Abhishek Kumar und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

X-ray examinations are integral to medical diagnostics but pose risks from ionizing radiation. Adhering to the ALARA (as low as reasonably achievable) principle in diagnostic radiography is essential. This study evaluates the accuracy and reliability of entrance skin dose (ESD) values displayed on digital radiographic X-ray machine by comparing them with estimated ESD values during common radiographic examinations. ESD was estimated for 250 radiographs of 150 patients (90 females, 60 males) undergoing five common radiographic views: lumbosacral (LS) spine anterior–posterior (AP)/lateral (LAT), pelvis AP, and abdomen supine/erect. Using the formula, estimated ESD values were calculated and compared with displayed ESD values from the console of the digital X-ray machine. The mean estimated and displayed ESD values were: LS spine AP (1.31 mGy, 0.92 mGy), LS spine LAT (2.12 mGy, 1.63 mGy), pelvis AP (0.69 mGy, 0.62 mGy), abdomen supine (0.67 mGy, 0.65 mGy), and abdomen erect (1.44 mGy, 1.06 mGy). Statistical analysis revealed a significant correlation between estimated and displayed ESD values across all views (p

Zitieren

APA

Kumar, A., Bhatt, S., Mishra, A., & Srivastava, A. (2026). Comparative Dosimetric Analysis of System Displayed versus Calculated Entrance Skin Dose in Routine Radiographic Imaging. Indian Journal of Radiology and Imaging. https://doi.org/10.1055/s-0046-1817157

Vancouver

Kumar A, Bhatt S, Mishra A, Srivastava A. Comparative Dosimetric Analysis of System Displayed versus Calculated Entrance Skin Dose in Routine Radiographic Imaging. Indian Journal of Radiology and Imaging. 2026. doi:10.1055/s-0046-1817157

BibTeX
@article{Kumar2026,
  author = {Kumar, Abhishek and Bhatt, Shuchi and Mishra, Atul and Srivastava, A.K.},
  title = {Comparative Dosimetric Analysis of System Displayed versus Calculated Entrance Skin Dose in Routine Radiographic Imaging},
  journal = {Indian Journal of Radiology and Imaging},
  year = {2026},
  doi = {10.1055/s-0046-1817157}
}
Kostenlos starten →