A Case Report of Acute Hemolysis after Endovascular Abdominal Aneurysm Repair with Onyx Embolization of Endoleak: A Clinical Conundrum
Journal of Clinical Interventional Radiology ISVIR · 15.10.2025
DOI: 10.1055/s-0045-1812286 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Clinical Interventional Radiology ISVIR, erschienen am 15.10.2025. Verfasst von Apratim Roy Choudhury und 3 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A 75-year-old gentleman with a large degenerative abdominal aortic aneurysm of diameter 7.5 cm underwent standard endovascular aneurysm repair with Endurant (Medtronic) stent graft. He underwent coil embolization of a small penetrating ulcer in the neck of the aneurysm, followed by liquid embolic agent (Onyx 18) injection in the aneurysm sac in view of endoleak. The procedure was uneventful with
Zitieren
APA
Choudhury, A. R., Valakkada, J., Ayappan, A., & Alex, A. (2025). A Case Report of Acute Hemolysis after Endovascular Abdominal Aneurysm Repair with Onyx Embolization of Endoleak: A Clinical Conundrum. Journal of Clinical Interventional Radiology ISVIR. https://doi.org/10.1055/s-0045-1812286
Vancouver
Choudhury AR, Valakkada J, Ayappan A, Alex A. A Case Report of Acute Hemolysis after Endovascular Abdominal Aneurysm Repair with Onyx Embolization of Endoleak: A Clinical Conundrum. Journal of Clinical Interventional Radiology ISVIR. 2025. doi:10.1055/s-0045-1812286
BibTeX
@article{Choudhury2025,
author = {Choudhury, Apratim Roy and Valakkada, Jineesh and Ayappan, Anoop and Alex, Ajay},
title = {A Case Report of Acute Hemolysis after Endovascular Abdominal Aneurysm Repair with Onyx Embolization of Endoleak: A Clinical Conundrum},
journal = {Journal of Clinical Interventional Radiology ISVIR},
year = {2025},
doi = {10.1055/s-0045-1812286}
}
EUVIMED