EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bilateral Fitting of Bone-Anchored Hearing Devices: Speech Recognition and Sound Localization

Cynthia Harumi Yokoyama Ueda iD, Isabela de Souza Jardim iD, Ricardo Ferreira Bento iD, Renata Marcial Soares iD

International Archives of Otorhinolaryngology · 01.10.2025 · 29 (04) · 001-007

DOI: 10.1055/s-0045-1810002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Archives of Otorhinolaryngology, erschienen am 01.10.2025. Verfasst von Cynthia Harumi Yokoyama Ueda und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Hospital das Clínicas, School of Medicine, Universidade de São Paulo, São Paulo, SP, Brazil. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bilateral fitting of bone-anchored hearing devices (BAHD) remains a contentious topic, as the use of a single device can direct sound to both cochleae. However, the interplay of interaural attenuation and time delay may result in different responses in each ear; thus, greater challenges for unilateral BAHD users. To assess the auditory performance of BAHD users with unilateral and bilateral fitting regarding speech recognition in silence and noise and sound localization. Cross-sectional study. Unilateral BAHD users treated at a Brazilian public hospital underwent a speech recognition test, containing a list of monosyllables at 65dBSPL in silence and noise (S/N ratio = 0dB). The sound localization test employed eight speakers arranged at 45° distance. A recorded trisyllabic word served as the stimulus. For bilateral fitting, an elastic band with a device similar to the implant was used; patients underwent the same tests under identical conditions. Sixteen patients were assessed (mean age = 24.2 years). The average monosyllable recognition in silence rate was 71.5% in unilateral fitting and 78.2% in bilateral fitting. In noise, 61% in unilateral fitting and 72.2% in bilateral fitting. The mean angular deviation for the sound localization test was 80.48° in unilateral fitting and 68.08° in bilateral fitting. The bilateral fitting outcomes were better for all tests. Users with bilateral BAHD fitting had better outcomes for speech recognition and sound localization.

Schlagwörter

Stichwörter der Autor:innen

bilateral hearing lossbone conductionbone-anchored prosthesiscorrection of hearing impairmenthearing aidsspeech discrimination tests

Autor:innen und Institutionen

  • Department of Otorhinolaryngology, Hospital das Clínicas, School of Medicine, Universidade de São Paulo, São Paulo, SP, Brazil.

ORCID-Profile: Cynthia Harumi Yokoyama Ueda, Isabela de Souza Jardim, Ricardo Ferreira Bento, Renata Marcial Soares

Zitieren

APA

Ueda, C. H. Y., Jardim, I. S., Bento, R. F., & Soares, R. M. (2025). Bilateral Fitting of Bone-Anchored Hearing Devices: Speech Recognition and Sound Localization. International Archives of Otorhinolaryngology, 29(04), 001-007. https://doi.org/10.1055/s-0045-1810002

Vancouver

Ueda CHY, Jardim IS, Bento RF, Soares RM. Bilateral Fitting of Bone-Anchored Hearing Devices: Speech Recognition and Sound Localization. International Archives of Otorhinolaryngology. 2025;29(04):001-007. doi:10.1055/s-0045-1810002

BibTeX
@article{Ueda2025,
  author = {Ueda, Cynthia Harumi Yokoyama and Jardim, Isabela de Souza and Bento, Ricardo Ferreira and Soares, Renata Marcial},
  title = {Bilateral Fitting of Bone-Anchored Hearing Devices: Speech Recognition and Sound Localization},
  journal = {International Archives of Otorhinolaryngology},
  year = {2025},
  volume = {29},
  number = {04},
  pages = {001--007},
  doi = {10.1055/s-0045-1810002}
}
Kostenlos starten →