EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Patient Satisfaction and Oral Health-Related Quality of Life of Quadrilateral Bar versus Bilateral Linear Bar for Mandibular Implant Overdenture: Randomized Controlled Clinical Trial

Patientenzufriedenheit und oral gesundheitsbezogene Lebensqualität von quadrilateralem Bar versus bilateralem linearem Bar bei mandibulärer Implantat-Overdenture: randomisierte kontrollierte klinische Studie

Heba Wageh Abozaed

European Journal of Dentistry · 01.05.2026 · 20 (02) · 630-637

DOI: 10.1055/s-0045-1809912 ↗

Auf einen Blick

Bei 20 Personen mit mandibulärer Implantat-Overdenture unterschieden sich Patientenzufriedenheit und OHRQoL je nach Bar-Design. Quadrilateral war besser bei Stabilität/Retention und Kauen, bilateral linear bei Komfort und Hygiene.

Fragestellung

Unterscheiden sich Patientenzufriedenheit und oral gesundheitsbezogene Lebensqualität bei mandibulären Implantat-Overdentures mit quadrilateralem versus bilateralem linearem Bar-Design?

Methode

Randomisierte kontrollierte klinische Studie mit 20 Teilnehmenden; vier Implantate pro Person im Bereich der Unterkiefer-Eckzähne und 1. Molaren; Vergleich nach 3 Monaten mittels VAS und OHIP-14.

Ergebnisse

Bei quadrilateralem Bar bessere Werte für Prothesenstütze/Retention (p = 0,034) und Beißen/Kauen (p = 0,019). Bei bilateral linearem Bar bessere Werte für Prothesenkomfort (p = 0,014) und Hygienemaßnahmen (p = 0,007); funktionelle Limitation höher (p = 0,02).

Schlussfolgerung der Autor:innen

Der quadrilaterale Bar war mit höherer Patientenzufriedenheit bei Stabilität/Retention und Kauen verbunden. Der bilaterale lineare Bar erhöhte die Zufriedenheit mit Komfort und hygienischen Maßnahmen.

Kernaussagen

  • Quadrilateral: bessere Prothesenstabilität/Retention
  • Bilateral linear: mehr Komfort und leichtere Hygiene
  • OHRQoL-Teilbereich funktionelle Limitation mit bilateral linear höher

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Dentistry, erschienen am 01.05.2026. Verfasst von Heba Wageh Abozaed. Beteiligte Einrichtung: Department of Prosthodontics, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj, Saudi Arabia. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate four implant complete mandibular overdentures retained with different bar designs regarding patient satisfaction and oral health-related quality of life (OHRQoL). Twenty participants were selected for this study. Each participant received four implants in the mandibular canine and first molar regions. All patients were divided into two equal groups based on their bar designs: quadrilateral (group I) and bilateral linear (group II). A visual analog scale (VAS) was used to quantify patient satisfaction, and OHRQoL was determined using the Oral Health Impact Profile (OHIP-14). Three months later, the VAS and OHIP-14 questions were evaluated. For properly distributed data, continuous variables were shown as mean ± standard deviation. The Mann–Whitney U test was used to compare the two groups. The significance criterion is set at the 5% level. When p < 0.05, the results were deemed significant. Patient satisfaction differs significantly between the two groups, as the quadrilateral bar designs enhance denture support and retention (p = 0.034*) and biting or chewing food (p = 0.019*). However, bilateral linear bar designs improve denture comfort (p = 0.014*) and hygiene practices (p = 0.007*). There were no significant variations between the two attachment designs in the remaining items of VAS and OHIP-14 questions, except that the bilateral linear bar configuration demonstrated higher scores in functional limitation (p = 0.02*). The quadrilateral bar demonstrated greater patient satisfaction than the bilateral linear bar regarding denture stability/retention and biting or chewing food. However, the bilateral linear bars increase patient satisfaction with denture comfort and the ease of hygienic procedures. Furthermore, regarding the functional limitations of the OHIP-14 questions, the bilateral linear bar provides higher scores than the quadrilateral ones.

Autor:innen und Institutionen

  • Department of Prosthodontics, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj, Saudi Arabia.
  • Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Eldakahlia, Egypt.

Zitieren

APA

Abozaed, H. W. (2026). Patient Satisfaction and Oral Health-Related Quality of Life of Quadrilateral Bar versus Bilateral Linear Bar for Mandibular Implant Overdenture: Randomized Controlled Clinical Trial. European Journal of Dentistry, 20(02), 630-637. https://doi.org/10.1055/s-0045-1809912

Vancouver

Abozaed HW. Patient Satisfaction and Oral Health-Related Quality of Life of Quadrilateral Bar versus Bilateral Linear Bar for Mandibular Implant Overdenture: Randomized Controlled Clinical Trial. European Journal of Dentistry. 2026;20(02):630-637. doi:10.1055/s-0045-1809912

BibTeX
@article{Abozaed2026,
  author = {Abozaed, Heba Wageh},
  title = {Patient Satisfaction and Oral Health-Related Quality of Life of Quadrilateral Bar versus Bilateral Linear Bar for Mandibular Implant Overdenture: Randomized Controlled Clinical Trial},
  journal = {European Journal of Dentistry},
  year = {2026},
  volume = {20},
  number = {02},
  pages = {630--637},
  doi = {10.1055/s-0045-1809912}
}
Kostenlos starten →