2D Shear Wave Elastography: An Evolving Technique for Comparison of Placental Elasticity in Normal and Preeclamptic Pregnancy
Indian Journal of Radiology and Imaging · 01.04.2026 · 36 (02) · 216-223
DOI: 10.1055/s-0045-1809683 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Radiology and Imaging, erschienen am 01.04.2026. Verfasst von Ritika Sihmar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiodiagnosis, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
This article evaluates differences in placental elasticity between normal and preeclamptic pregnancies using shear wave elastography and assesses the potential of the placental elasticity values in predicting preeclampsia. The study included 60 pregnant women, 30 diagnosed with preeclampsia and 30 with normal pregnancies, in their second and third trimesters. Shear wave elastography was performed to assess placental elasticity. Both mean (average) and maximum elasticity values were recorded and cutoff values were determined using receiver operating characteristic (ROC) curve analysis to evaluate their potential in predicting preeclampsia. Placental elasticity values were significantly higher in preeclamptic women (group A) compared with healthy pregnant women (group B). The mean elasticity in group A was 15.74 ± 3.51 kPa, with a maximum elasticity of 27.4 ± 4.66 kPa; whereas in group B, the corresponding values were 4.42 ± 1.93 and 7.13 ± 3.05 kPa, respectively (p < 0.0001). In preeclampsia cases, the shear wave modulus was higher in the central region of the placenta than at the edges. ROC curve analysis evaluated a mean elasticity cutoff value of 8.1 kPa, with a sensitivity of 100%, specificity of 96.67%, positive predictive value of 96.8%, negative predictive value of 100%, and a diagnostic accuracy of 98.33%. The study revealed significant differences in placental elasticity between preeclamptic and healthy pregnancies, highlighting the potential of shear wave elastography as a valuable tool for early prediction of preeclampsia. Early prediction using this method could significantly reduce maternal and perinatal mortality and morbidity, especially in developing countries, by identifying cases before the onset of clinical symptoms.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiodiagnosis, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, India.
- Department of Obstetrics and Gynaecology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, India.
Zitieren
APA
Sihmar, R., Bano, S., & Malik, R. (2026). 2D Shear Wave Elastography: An Evolving Technique for Comparison of Placental Elasticity in Normal and Preeclamptic Pregnancy. Indian Journal of Radiology and Imaging, 36(02), 216-223. https://doi.org/10.1055/s-0045-1809683
Vancouver
Sihmar R, Bano S, Malik R. 2D Shear Wave Elastography: An Evolving Technique for Comparison of Placental Elasticity in Normal and Preeclamptic Pregnancy. Indian Journal of Radiology and Imaging. 2026;36(02):216-223. doi:10.1055/s-0045-1809683
BibTeX
@article{Sihmar2026,
author = {Sihmar, Ritika and Bano, Shahina and Malik, Renuka},
title = {2D Shear Wave Elastography: An Evolving Technique for Comparison of Placental Elasticity in Normal and Preeclamptic Pregnancy},
journal = {Indian Journal of Radiology and Imaging},
year = {2026},
volume = {36},
number = {02},
pages = {216--223},
doi = {10.1055/s-0045-1809683}
}
EUVIMED