EUVIMEDEUVIMED entdecken
Crossref

Investigation of the I-131 Contamination Risk after Radioiodine Therapy in Patient Rooms

A Haslauer, S Nekolla

Nuklearmedizin - NuclearMedicine · 01.03.2025 · 64 (01) · 114

DOI: 10.1055/s-0045-1804474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.03.2025. Verfasst von A Haslauer und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ziel/Aim: Radioiodine (I-131) therapy is a common treatment for thyroid diseases. Contamination can occur in the patient rooms during their mandatory stay. In this study, the contamination risk in patient rooms after radioiodine therapy is investigated. Methodik/Methods: Wipe samples were collected every day for 25 patients that underwent I-131 therapy on 6 positions: Entrance door handle, bathroom door handle, faucet, chairs and toilet seat. The floor was screened for contamination after patient release and a sample was taken in case of a contamination. According to DIN ISO 7503-2, which gives the guidance in performing wipe tests for contamination, the wipe itself can only gather 10% of the actual contamination. Therefore a factor 10 is used in the results. The occurring error therefore is not to be neglected [ 1 ]. The probes were measured in a gamma counter for 10 minutes each. Ergebnisse/Results: The contamination on surfaces were highest in bathrooms, especially the toilet seat with a mean of 1.6 kBq/m2 (min=0.0 kBq/m2, max=16.2 kBq/m2). The other surfaces ranged on average from 0.2 kBq/m2 to 1.0 kBq/m2 with a maximum contamination of 12.8 kBq/m2 on the faucet. The floor contamination around the bed showed a mean of 9.1 kBq/m2 (min=0.1 kBq/m2, max=75.5 kBq/m2), while in the bathroom it showed 24.0 kBq/m2 (min=1.0 kBq/m2, max=124.5 kBq/m2). After the room was cleaned the only notable contamination was found on toilet seats with an average of 0.4 kBq/m2 (min=0.0 kBq/m2, max=2.0 kBq/m2). Schlussfolgerungen/Conclusions: The contamination on surfaces and the floor of patient beds after radioiodine therapy show a predictable distribution and have the potential to be spread by the medical staff. Assuming that the staff is trained in radiation protection, this contamination will not lead to any effective dose. Since I-131 can also be exhaled, the staff gets an incorparation screening every week to assure the effective dose is below a critical value. Publication History Article published online: 12 March 2025 © 2025. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Haslauer, A., & Nekolla, S. (2025). Investigation of the I-131 Contamination Risk after Radioiodine Therapy in Patient Rooms. Nuklearmedizin - NuclearMedicine, 64(01), 114. https://doi.org/10.1055/s-0045-1804474

Vancouver

Haslauer A, Nekolla S. Investigation of the I-131 Contamination Risk after Radioiodine Therapy in Patient Rooms. Nuklearmedizin - NuclearMedicine. 2025;64(01):114. doi:10.1055/s-0045-1804474

BibTeX
@article{Haslauer2025,
  author = {Haslauer, A and Nekolla, S},
  title = {Investigation of the I-131 Contamination Risk after Radioiodine Therapy in Patient Rooms},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2025},
  volume = {64},
  number = {01},
  pages = {114},
  doi = {10.1055/s-0045-1804474}
}
Kostenlos starten →