EUVIMEDEUVIMED entdecken
Crossref

Total-body [18F]FDG-PET/CT imaging of healthy controls with minimal effective subject dose

D Ferrara, S Gutschmayer, M Pires, B Geist, M Hacker, W Langsteger, I Rausch, L K Shiyam Sundar, T Beyer

Nuklearmedizin - NuclearMedicine · 01.03.2025 · 64 (01) · 66

DOI: 10.1055/s-0045-1804341 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.03.2025. Verfasst von D Ferrara und 8 weiteren Autor:innen. Die Arbeit nennt 2 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ziel/Aim: Total-body (TB) PET/CT systems offer increased sensitivity, enabling low-tracer-activity protocols. AI-driven methods can generate CT-like attenuation maps from raw PET data. Combining these approaches may lower subject exposure, making TB-PET/CT suitable for screening healthy individuals to evaluate whole-body metabolism in the absence of disease. Methodik/Methods: 50 healthy controls underwent a test-retest imaging protocol (5-week interval) using a Siemens QUADRA TB-PET system. Subjects fasted for 6 hours before a (113±5) MBq [18F]FDG injection and underwent a 60-min listmode PET scan with a low-dose (1 mSv) CT scan (supine/arms down). Ten controls (6F/4M, BMI 24±4 kg/m²) were included in a first, interim, analysis, focused on the static PET acquired at 55-60 min p.i. Emission counts were removed randomly from PET-listmode files of 55-60 min p.i. to simulate lower tracer activities: 100%, 50%, 25%, 10%, and 5%. Effective doses (ED) were estimated for each activity level. Synthetic CT images (ED=0 mSv) were created with the CTlessPET [ 1 ] software and used for reconstructing attenuation-corrected PET images. The original CTs were segmented in multiple volumes of interest using MOOSE [ 2 ]. Mean standardized uptake-values normalized to body weight (SUVbw) and coefficients of variation (COV) were extracted and compared across the 5 activity levels. Ergebnisse/Results: PET-related ED decreased from (2.9±0.3) mSv at 100% counts to (0.1±0.05) mSv at 5% counts. Mean SUVbw at 100% dose ranged from 0.4±0.1 (lungs) to 3.0±0.3 (kidneys). Minimal SUVbw group variations (%-difference

Zitieren

APA

Ferrara, D., Gutschmayer, S., Pires, M., Geist, B., Hacker, M., Langsteger, W., Rausch, I., Sundar, L. K. S., & Beyer, T. (2025). Total-body [18F]FDG-PET/CT imaging of healthy controls with minimal effective subject dose. Nuklearmedizin - NuclearMedicine, 64(01), 66. https://doi.org/10.1055/s-0045-1804341

Vancouver

Ferrara D, Gutschmayer S, Pires M, Geist B, Hacker M, Langsteger W, et al. Total-body [18F]FDG-PET/CT imaging of healthy controls with minimal effective subject dose. Nuklearmedizin - NuclearMedicine. 2025;64(01):66. doi:10.1055/s-0045-1804341

BibTeX
@article{Ferrara2025,
  author = {Ferrara, D and Gutschmayer, S and Pires, M and Geist, B and Hacker, M and Langsteger, W and Rausch, I and Sundar, L K Shiyam and Beyer, T},
  title = {Total-body [18F]FDG-PET/CT imaging of healthy controls with minimal effective subject dose},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2025},
  volume = {64},
  number = {01},
  pages = {66},
  doi = {10.1055/s-0045-1804341}
}
Kostenlos starten →