EUVIMEDEUVIMED entdecken
Crossref

Radiation Exposure in [18F]-PSMA-1007 specimen PET-CT Intraoperative Imaging Procedures

J Kandziora, A Moraitis, C Darr, K Herrmann, W Fendler, U Krafft, B Hadaschik, H A Devendranath, P Fragoso Costa

Nuklearmedizin - NuclearMedicine · 01.03.2025 · 64 (01) · 65

DOI: 10.1055/s-0045-1804338 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.03.2025. Verfasst von J Kandziora und 8 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ziel/Aim: The current study examines the occupational exposure of robot-assisted prostatectomy and open surgery using a specimen PET-CT in combination with [18F]F-PSMA-1007. The patients received PET-CT/-MR on the same day. The goal is to obtain a quantitative description of the radiation exposure of these procedures and determine how often the operation can be performed without reaching the annual dose limit of 1 mSv or 6 mSv for category B monitored persons. Methodik/Methods: Twelve high-risk prostate cancer patients received PSMA-PET-CT/-MR prior to prostatectomy to exclude metastasis. The surgeon, first assistant, and nurse were equipped with an electronic personal dosimeter to monitor the personal dose equivalent Hp(10) during surgery. A specific dose rate coefficient was determined from ambient dose equivalent rate [H*(10)] measurements in 8 patients. In addition, a fixed-distance exposure model was used to predict occupational exposure for the staff members relative to a point source (0.3, 0.6, and 1.0 m for the first assistant, scrub nurse, and surgeon). Ergebnisse/Results: Patients received a mean±standard deviation of 302±54 MBq of [18F]F-PSMA-1007. The time between injection and surgery was 3.15±0.91 hours, and surgery lasted 3.26±0.88 hours. In 11 out of 12 procedures, the first assistant received the highest Hp(10). The measured Hp(10) was 28.8±10.8 µSv for the first assistant, 8.6±7.1 µSv for the nurse, and 14.5±8.4 µSv for the surgeon. The specific dose rate coefficient was 0.0287±0.009 µSv/(h*MBq). The estimated Hp(10) for the first assistant was 49.8±21.3 µSv, for the nurse 4.5±1.9 µSv, and for the surgeon 12.4±5.3 µSv. The correlation coefficients between the point source model and the measured dose were 0.52 for the first assistant, 0.03 for the surgeon, and 0.70 for the nurse. Schlussfolgerungen/Conclusions: A single team could perform this operation approximately 35 times annually without exceeding the population limit of 1 mSv. A category B monitored person could perform it about 210 times annually. The first assistant, closest to the patient, is the limiting factor. The model appears to overestimate Hp(10) for the first assistant and nurse while underestimating it for the surgeon, illustrating the limitations of a fixed-distance point source model. Publication History Article published online: 12 March 2025 © 2025. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Kandziora, J., Moraitis, A., Darr, C., Herrmann, K., Fendler, W., Krafft, U., Hadaschik, B., Devendranath, H. A., & Costa, P. F. (2025). Radiation Exposure in [18F]-PSMA-1007 specimen PET-CT Intraoperative Imaging Procedures. Nuklearmedizin - NuclearMedicine, 64(01), 65. https://doi.org/10.1055/s-0045-1804338

Vancouver

Kandziora J, Moraitis A, Darr C, Herrmann K, Fendler W, Krafft U, et al. Radiation Exposure in [18F]-PSMA-1007 specimen PET-CT Intraoperative Imaging Procedures. Nuklearmedizin - NuclearMedicine. 2025;64(01):65. doi:10.1055/s-0045-1804338

BibTeX
@article{Kandziora2025,
  author = {Kandziora, J and Moraitis, A and Darr, C and Herrmann, K and Fendler, W and Krafft, U and Hadaschik, B and Devendranath, H A and Costa, P Fragoso},
  title = {Radiation Exposure in [18F]-PSMA-1007 specimen PET-CT Intraoperative Imaging Procedures},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2025},
  volume = {64},
  number = {01},
  pages = {65},
  doi = {10.1055/s-0045-1804338}
}
Kostenlos starten →