Drainage of walled-off pancreatic necrosis using EUS-guided lumen apposing metal stents (LAMS) with and without electro-cautery
Zeitschrift für Gastroenterologie · 01.09.2024 · 62 (09) · e797
DOI: 10.1055/s-0044-1790034 ↗Kurz gefasst
Fachartikel in der Zeitschrift Zeitschrift für Gastroenterologie, erschienen am 01.09.2024. Verfasst von N. Bekkali und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Background
In recent years EUS-guided drainage using lumen-apposing metal stents (LAMS) has become the first-choice treatment of symptomatic walled-off necrosis (WON). The development of lumen apposing stents (LAMS), fully covered self-expanding metal stents with a special design of the flanches and large diameter, improved the drainage of debris and facilitated further direct endoscopic necrosectomy. Delivery systems with integrated electro-cautery (EC) enable direct access and stent deployment whilst the conventional stent insertion requires several steps including access using a needle or cystotome, wire insertion and enlargement of the created tract before the stent placement.
Aims
In this study, we aimed to compare the practicality of EUS-guided procedures and their outcome between conventional LAMS (cLAMS) and those with integrated EC (LAMS-EC).
Methods
From a prospectively maintained database, data from consecutive patients undergoing EUS-guided LAMS insertion with or without integrated electro-cautery were collected, Data on procedure time, sedation, technical and clinical success as well as adverse events were analysed. Infection of the WOPN, biliary compression, gastric outlet obstruction were accepted indications for intervention. The time of intervention was at least 4 weeks after onset of symptoms of acute pancreatitis.
Results
In this single centre study, we analysed 107 consecutive procedures of transmural EUS-guided stenting for drainage of walled-off necrosis. 39 cLAMS and 68 LAMS-EC were placed successfully. Mean WON size was 12.9±4.2 cm with mean 30%±15% solid necrosis. Procedure times were shorter with LAMS-EC (18 .0±6.6 min vs. 39.7±8.3 min; p
Zitieren
APA
Bekkali, N., Selvaraj, E., Dietrich, C. F., & Braden, B. (2024). Drainage of walled-off pancreatic necrosis using EUS-guided lumen apposing metal stents (LAMS) with and without electro-cautery. Zeitschrift für Gastroenterologie, 62(09), e797. https://doi.org/10.1055/s-0044-1790034
Vancouver
Bekkali N, Selvaraj E, Dietrich CF, Braden B. Drainage of walled-off pancreatic necrosis using EUS-guided lumen apposing metal stents (LAMS) with and without electro-cautery. Zeitschrift für Gastroenterologie. 2024;62(09):e797. doi:10.1055/s-0044-1790034
BibTeX
@article{Bekkali2024,
author = {Bekkali, N. and Selvaraj, E. and Dietrich, C. F and Braden, B.},
title = {Drainage of walled-off pancreatic necrosis using EUS-guided lumen apposing metal stents (LAMS) with and without electro-cautery},
journal = {Zeitschrift für Gastroenterologie},
year = {2024},
volume = {62},
number = {09},
pages = {e797},
doi = {10.1055/s-0044-1790034}
}
EUVIMED