EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Study on Preparation Technology and Quality Standard of Acne Granules

Bo Dai, Fang Wang, Yan Geng, Chen Chen, Min Zhou, Lingyu Hang

Pharmaceutical Fronts · 01.09.2024 · 06 (03) · e305-e314

DOI: 10.1055/s-0044-1789234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceutical Fronts, erschienen am 01.09.2024. Verfasst von Bo Dai und 5 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The study aimed to optimize the preparation process of acne granules and establish their quality standards. In this work, the extraction process of Chinese herbal extract was optimized by the amount of water added, the number of decoction, the extraction time, and the soaking time with extraction yield as an evaluation index. The indexes of the acne granules such as molding rate, dissolvability, angle of repose, moisture content, and ease of preparation were evaluated. Thin-layer chromatography (TLC) was used to identify Salviae, Scutellaria baicalensis, and Indigowoad Leaf. High-performance liquid chromatography (HPLC) was used to determine the baicalin content in the granules. Based on orthogonal and single-factor experiments, the optimized extraction process of the prescription of nine medicinal materials was as follows: soaked in cold water for 2 hours, boiled three times, decocted with eight times the amount of water for 1.5 hours for the first time, and six times the amount of water for 1 hour for the second and third times. The combined extracts were concentrated to a relative density of 1.30 to 1.40 (20–30°C), and mixed evenly according to the mass ratio of extract to excipient 1:5, and dextrin: powdered sugar = 1:3. The mixture was granulated, dried, prepared into granules, and the acne granules were formed at a molding rate of 95.52% and a critical relative humidity of 82%. The spots in TLC were clear and easy to identify. The HPLC result showed that the content of baicalin was not less than 1.0 mg/g. The study provides a valuable reference for the production and preparation of the granules through optimization of the wet process and the excipient dosage. Furthermore, the established TLC method for the identification and the HPLC method for baicalin quantification laid the foundation for the quality control of the preparation in future studies.

Zitieren

APA

Dai, B., Wang, F., Geng, Y., Chen, C., Zhou, M., & Hang, L. (2024). Study on Preparation Technology and Quality Standard of Acne Granules. Pharmaceutical Fronts, 06(03), e305-e314. https://doi.org/10.1055/s-0044-1789234

Vancouver

Dai B, Wang F, Geng Y, Chen C, Zhou M, Hang L. Study on Preparation Technology and Quality Standard of Acne Granules. Pharmaceutical Fronts. 2024;06(03):e305-e314. doi:10.1055/s-0044-1789234

BibTeX
@article{Dai2024,
  author = {Dai, Bo and Wang, Fang and Geng, Yan and Chen, Chen and Zhou, Min and Hang, Lingyu},
  title = {Study on Preparation Technology and Quality Standard of Acne Granules},
  journal = {Pharmaceutical Fronts},
  year = {2024},
  volume = {06},
  number = {03},
  pages = {e305--e314},
  doi = {10.1055/s-0044-1789234}
}
Kostenlos starten →