In Vitro Biomechanical Study of Femoral Neck Fracture Fixation with Two or Three Cannulated Screws in Dogs
Veterinary and Comparative Orthopaedics and Traumatology · 01.01.2025 · 38 (01) · 018-024
DOI: 10.1055/s-0044-1788802 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.01.2025. Verfasst von Fátima Maria C Caldeira und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Surgery and Animal Reproduction, School of Veterinary Medicine and Animal Science-São Paulo State University (UNESP), Rubião…. Hauptthemen laut MEDLINE: Bone Screws, Femoral Neck Fractures, Fracture Fixation, Internal. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
Objective
To evaluate the in vitro mechanical properties of basilar fractures of the femoral neck stabilized with two or three titanium-cannulated screws in dogs. Study Design Ex vivo study. Sample Population Cadaveric canine femur (n = 21).
Methods
The bones were divided as follows: Group 1: control (no osteotomy); Group 2: osteotomy and stabilization with two cannulated screws; and Group 3: osteotomy and stabilization with three cannulated screws. All groups were tested with destructive axial compression with load applied to the femoral head. The stiffness, load, and displacement were evaluated at the failure of Group 1, and the yield load and displacement of Groups 2 and 3.
Results
The placement of the three cannulated screws was more demanding than two cannulated screws because of the risk of cortical perforation, especially in the trochanteric fossa area. The smaller the width of the femoral neck, the higher the risk of cortical bone wall perforation. The intact control bones were stiffer (674 N/mm) than both the two-screw repair (90 N/mm) and three-screw repair (120 N/mm) groups (p < 0.05). The failure load was greatest for Group 1 (2692 N). The yield loads for Groups 3 and 2 were 586 and 303 N, respectively. There was no difference between groups for displacement.
Conclusion
In vitro cadaveric models of femoral neck basilar fractures repaired with three cannulated screws were significantly stronger than two cannulated screws, but the clinical efficacy must be evaluated by comparing them in vitro with noncannulated stainless steel screws.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Veterinary Surgery and Animal Reproduction, School of Veterinary Medicine and Animal Science-São Paulo State University (UNESP), Rubião Júnior s/n, Botucatu, São Paulo, Brazil.
- LEMM-Laboratório de Ensaios Mecânicos, Jaú, São Paulo, Brazil.
- Facultad Medicina Veterinaria y Zootecnia, Universidad del Tolima, Colômbia.
- Facultad de Ciencias Veterinarias (cátedra de Enfermedades Quirúrgicas), Universidade de Buenos Aires, Argentina.
- Campinas, São Paulo, Brazil.
ORCID-Profile: Fátima Maria C Caldeira, Guilherme R Cassanego
Zitieren
APA
Caldeira, F. M. C., Rahal, S. C., Cassanego, G. R., Ribeiro, C. R., Serrato, S. A. A., Mele, C. E., & Masseran, P. (2025). In Vitro Biomechanical Study of Femoral Neck Fracture Fixation with Two or Three Cannulated Screws in Dogs. Veterinary and Comparative Orthopaedics and Traumatology, 38(01), 018-024. https://doi.org/10.1055/s-0044-1788802
Vancouver
Caldeira FMC, Rahal SC, Cassanego GR, Ribeiro CR, Serrato SAA, Mele CE, et al. In Vitro Biomechanical Study of Femoral Neck Fracture Fixation with Two or Three Cannulated Screws in Dogs. Veterinary and Comparative Orthopaedics and Traumatology. 2025;38(01):018-024. doi:10.1055/s-0044-1788802
BibTeX
@article{Caldeira2025,
author = {Caldeira, Fátima Maria C and Rahal, Sheila C and Cassanego, Guilherme R and Ribeiro, Celso R and Serrato, Sergio A A and Mele, Carlos E and Masseran, Paulo},
title = {In Vitro Biomechanical Study of Femoral Neck Fracture Fixation with Two or Three Cannulated Screws in Dogs},
journal = {Veterinary and Comparative Orthopaedics and Traumatology},
year = {2025},
volume = {38},
number = {01},
pages = {018--024},
doi = {10.1055/s-0044-1788802}
}
EUVIMED