EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A New Concept Custom-Made Branchless Aortic Endograft in Complex Anatomies

C. Galeandro, R. Prunella, F. Guarini, S. Pisanello, L. Cimoli, G. La Barbera

AORTA · 01.10.2023 · 11 (05) · 1-18

DOI: 10.1055/s-0044-1787928 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AORTA, erschienen am 01.10.2023. Verfasst von C. Galeandro und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In aortic aneurysms with complex anatomy the aortic stent graft (ASG} must be released in a healthy landing zone but if it isn't possible, other techniques should be required such as fenestrated or branched stent-grafts or parallel grafts technique. In the Unit of Vascular and Endovascular Surgery of the Santissima Annunziata Hospital in Taranto (ITALY) we performed EVAR technique in complex anatomies using a new custom-made ASG: the Dominus® (EndoVsmart and Braile Biomedica). It is composed by a bifurcated main body in which stents configuration, amplitude of fenestrations and independent nitinol bared stents interconnected by Dacron collars, modulate the radial force respecting the aortic anatomy and allowing visceral perfusion. We employed this endograft in two patients: a 74 yo women with an asymptomatic pararenal abdominal aneurysm and a 73 yo man with an asymptomatic type IV thoraco-abdominal aneurysm. Both patients presented complex anatomies because of proximal landing zone, aortic angulation and aneurysmal involvement of visceral vessels. For these reasons the Dominus® custom-made branchless endograft was chosen. In the first case, pararenal aortic aneurysm presented CT, SMA and superior renal artery (the right one) arising at less than 1 cm one vessel to the other, so the graft was designed with three bare nitinol stents, interconnected by 5mm length Dacron collar, allowing all visceral arteries perfusion ([ Fig. 1 ]). In the other case, the type IV thoraco-abdominal aneurysm was treated with a graft designed with a 122° fenestration for both CT and SMA and a 360° fenestration at the level of renal arteries ([ Fig. 2 ]). In each procedure all visceral perfusion was guaranteed, devices were 24 Fr OD, fluoroscopy time was less than 800 seconds, 150 ml of contrast medium were used and patients were discharged with a single antiplatelet drug within 5 days after surgery. Fig. 1 Fig. 2 Publication History Article published online: 11 June 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

Zitieren

APA

Galeandro, C., Prunella, R., Guarini, F., Pisanello, S., Cimoli, L., & Barbera, G. L. (2023). A New Concept Custom-Made Branchless Aortic Endograft in Complex Anatomies. AORTA, 11(05), 1-18. https://doi.org/10.1055/s-0044-1787928

Vancouver

Galeandro C, Prunella R, Guarini F, Pisanello S, Cimoli L, Barbera GL. A New Concept Custom-Made Branchless Aortic Endograft in Complex Anatomies. AORTA. 2023;11(05):1-18. doi:10.1055/s-0044-1787928

BibTeX
@article{Galeandro2023,
  author = {Galeandro, C. and Prunella, R. and Guarini, F. and Pisanello, S. and Cimoli, L. and Barbera, G. La},
  title = {A New Concept Custom-Made Branchless Aortic Endograft in Complex Anatomies},
  journal = {AORTA},
  year = {2023},
  volume = {11},
  number = {05},
  pages = {1--18},
  doi = {10.1055/s-0044-1787928}
}
Kostenlos starten →