EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC-ND 4.0

Volar Plate Draping (VPD) for Severely Comminuted Proximal Phalanx Head Fractures

Ashwini Varadha Rajan iD, Vigneswaran Varadharajan iD, Praveen Bhardwaj iD, S Raja Sabapathy iD

Indian Journal of Plastic Surgery · 01.12.2024 · 57 (S 01 S 01) · S123-S127

DOI: 10.1055/s-0044-1787849 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Indian Journal of Plastic Surgery, erschienen am 01.12.2024. Verfasst von Ashwini Varadha Rajan und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Plastic, Hand and Reconstructive Microsurgery, Ganga Medical Center and Hospitals, Coimbatore, Tamil Nadu, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While proximal phalangeal joint injuries with comminution of the base of the middle phalanx are common injuries, proximal interphalangeal (PIP) joint fracture dislocations with an intact base of middle phalanx and a comminuted head of proximal phalanx are rare. Volar plate arthroplasty and other described techniques prevail for the former injury, while the latter does not have any supportive literature on the exact method of management. We herein present a 20-year-old male with a severely comminuted head of proximal phalanx fracture with dislocation of the PIP joint, which was not reconstructable but was managed successfully with a novel technique of volar plate draping that resurfaced the raw phalangeal head. A 3-year follow-up of the patient, whose finger has full, painless, and complete functional range of movement, gives us the belief that this procedure can provide a fully functional finger where other methods fail to do so.

Schlagwörter

Stichwörter der Autor:innen

ArthroplastyPIP Joint FracturesProximal Phalanx Head FracturesResurfacingVolar Plate

Autor:innen und Institutionen

  • The Department of Plastic, Hand and Reconstructive Microsurgery, Ganga Medical Center and Hospitals, Coimbatore, Tamil Nadu, India.

ORCID-Profile: Ashwini Varadha Rajan, Vigneswaran Varadharajan, Praveen Bhardwaj, S Raja Sabapathy

Zitieren

APA

Varadha Rajan, A., Varadharajan, V., Bhardwaj, P., & Sabapathy, S. R. (2024). Volar Plate Draping (VPD) for Severely Comminuted Proximal Phalanx Head Fractures. Indian Journal of Plastic Surgery, 57(S 01 S 01), S123-S127. https://doi.org/10.1055/s-0044-1787849

Vancouver

Varadha Rajan A, Varadharajan V, Bhardwaj P, Sabapathy SR. Volar Plate Draping (VPD) for Severely Comminuted Proximal Phalanx Head Fractures. Indian Journal of Plastic Surgery. 2024;57(S 01 S 01):S123-S127. doi:10.1055/s-0044-1787849

BibTeX
@article{VaradhaRajan2024,
  author = {Varadha Rajan, Ashwini and Varadharajan, Vigneswaran and Bhardwaj, Praveen and Sabapathy, S Raja},
  title = {Volar Plate Draping (VPD) for Severely Comminuted Proximal Phalanx Head Fractures},
  journal = {Indian Journal of Plastic Surgery},
  year = {2024},
  volume = {57},
  number = {S 01 S 01},
  pages = {S123--S127},
  doi = {10.1055/s-0044-1787849}
}
Kostenlos starten →