The Arterial System of the Fasciocutaneous Deltoid Flap Pedicle on 320-Detector Row Computed Tomography and Clinical Application in the Foot and Hand
Journal of Reconstructive Microsurgery · 01.01.2025 · 41 (01) · 077-084
DOI: 10.1055/s-0044-1787774 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.01.2025. Verfasst von Nguyen Ngoc-Huyen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Upper Extremity Surgery and Microsurgery, Institute of Traumatology, Orthopedics and Plastic Surgery, Central Hospital 108, Hanoi, Viet…. Hauptthemen laut MEDLINE: Plastic Surgery Procedures, Computed Tomography Angiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
Background
Fasciocutaneous free deltoid flaps are used to reconstruct hand, foot, and maxillofacial defects. Although anatomical studies of this flap pedicle have been performed on cadavers, there are no reports on the use of 320-detector row computed tomography angiography (CTA-320) to investigate the deltoid flap pedicle in living humans. This study aimed to investigate the arterial characteristics of the deltoid flap pedicle using the CTA-320 system in living humans.
Methods
Twenty-seven adult Vietnamese patients with 54 healthy deltoid regions underwent CTA-320 to investigate arterial blood supply before clinical free-flap transfer. Two- and three-dimensional reconstruction images of the arterial pedicle were visualized, and clinical reconstruction results were evaluated.
Results
The cutaneous vessel branches of the deltoid flap were separated from the posterior circumflex humeral artery (PCHA) and originated from the axillary (77.78%), subscapular (12.96%), and brachial (9.26%) arteries. The PCHA penetrated the quadrangular space in 90.74% of patients. The cutaneous arterial branch was present in the deltoid-triceps groove in 100% of patients. The average diameter and length of the PCHA were 3.38 ± 0.58 and 43.08 ± 6.60 mm, respectively. The average diameter and length of the flap cutaneous branch were 1.49 ± 0.28 and 44.57 ± 4.83 mm, respectively. The findings of CTA-320 were aligned with the intraoperative clinical findings well. All deltoid flaps were successfully free-transferred with good outcomes.
Conclusion
The CTA-320 is a practical and effective method for investigating deltoid flap pedicles. It enables accurate flap design and harvesting of flaps, thereby enhancing the clinical success of free-flap transfer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Upper Extremity Surgery and Microsurgery, Institute of Traumatology, Orthopedics and Plastic Surgery, Central Hospital 108, Hanoi, Vietnam.
- Department of Diagnosis Imaging, Central Hospital 108, Hanoi, Vietnam.
- Department of Plastic and Reconstructive Surgery, Technical University of Munich, Munich, Germany.
ORCID-Profile: Nguyen Ngoc-Huyen, Nguyen The-Hoang, Khanh Lam
Zitieren
APA
Ngoc-Huyen, N., The-Hoang, N., Lam, K., Quang-Vinh, N., & Staudenmaier, R. (2025). The Arterial System of the Fasciocutaneous Deltoid Flap Pedicle on 320-Detector Row Computed Tomography and Clinical Application in the Foot and Hand. Journal of Reconstructive Microsurgery, 41(01), 077-084. https://doi.org/10.1055/s-0044-1787774
Vancouver
Ngoc-Huyen N, The-Hoang N, Lam K, Quang-Vinh N, Staudenmaier R. The Arterial System of the Fasciocutaneous Deltoid Flap Pedicle on 320-Detector Row Computed Tomography and Clinical Application in the Foot and Hand. Journal of Reconstructive Microsurgery. 2025;41(01):077-084. doi:10.1055/s-0044-1787774
BibTeX
@article{NgocHuyen2025,
author = {Ngoc-Huyen, Nguyen and The-Hoang, Nguyen and Lam, Khanh and Quang-Vinh, Nguyen and Staudenmaier, Rainer},
title = {The Arterial System of the Fasciocutaneous Deltoid Flap Pedicle on 320-Detector Row Computed Tomography and Clinical Application in the Foot and Hand},
journal = {Journal of Reconstructive Microsurgery},
year = {2025},
volume = {41},
number = {01},
pages = {077--084},
doi = {10.1055/s-0044-1787774}
}