Complete Closed-Loop Ventilatory Circuit Delays the Onset of Ventilator-Associated Pneumonia in Mechanically Ventilated Neurological Patients in the ICU: A Single-Center Prospective Preliminary Study
Geschlossener kompletter Beatmungskreislauf verzögert den Beginn einer beatmungsassoziierten Pneumonie bei mechanisch beatmeten neurologischen Patient:innen auf der ICU: eine einzentrumige prospektive Vorstudie
Journal of Neuroanaesthesiology and Critical Care · 01.06.2024 · 11 (02) · 093-099
DOI: 10.1055/s-0044-1787541 ↗Auf einen Blick
Bei neurologischen Patient:innen unter invasiver Beatmung war die VAP-Rate mit geschlossenem Kreislauf ähnlich wie mit offenem System. Der VAP-Beginn trat im geschlossenen Arm später auf.
Fragestellung
Vergleicht ein konventioneller Beatmungskreislauf mit offenem Absaugen gegenüber DHWC mit geschlossenem Absaugen die VAP-Inzidenz bei neurologischen Patient:innen auf der Neuro-ICU?
Methode
Einzentrumige prospektive Kohortenstudie in einer tertiären Klinik; neurologische Patient:innen auf der Neuro-ICU mit MV >48 Stunden; Beobachtung der ersten 14 Tage der MV.
Ergebnisse
63 Patient:innen: 32 offen, 31 geschlossen. VAP-Inzidenz 9,3 % vs. 12,9 % (p = 0,8). Alle Fälle waren spät (>96 Stunden). VAP-Beginn Tag 7 vs. Tag 11.
Schlussfolgerung der Autor:innen
Die VAP-Inzidenzen waren in beiden Gruppen ähnlich. Neurologische Patient:innen mit kurzer MV-Dauer könnten vom DHWC mit geschlossenem Absaugsystem profitieren, da VAP später auftrat.
Kernaussagen
- VAP-Inzidenz: 9,3 % offen vs. 12,9 % geschlossen
- VAP-Beginn später im geschlossenen Arm: Tag 11 vs. Tag 7
- Dauer von MV, Neuro-ICU- und Krankenhausaufenthalt sowie Mortalität ohne Unterschied
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuroanaesthesiology and Critical Care, erschienen am 01.06.2024. Verfasst von Archana K. Raichurkar und 4 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Pneumonieprophylaxe
Abstract (Originalsprache)
Background
Ventilator-associated pneumonia (VAP) is preventable yet its incidence remains high. We compared conventional ventilator circuit with open suction and dual heated wire circuit (DHWC) with closed suction on the incidence of VAP.
Methods
This is a single-center, prospective cohort study conducted at a tertiary care hospital in neurological patients admitted to the neuro-intensive care unit (neuro-ICU) and requiring mechanical ventilation (MV) for more than 48 hours. Patients were ventilated using either conventional ventilator circuit with open suction (open group) or DHWC with closed suction (closed group) and were observed for VAP during the first 14 days of MV. The incidence and day of onset of VAP, duration of MV, duration of neuro-ICU and hospital stay, and mortality was noted in each group.
Results
A total of 63 patients were included (32 in open and 31 in closed group). The incidence of VAP was 9.3% in the open group and 12.9% in the closed group (p = 0.8). All the patients developed late VAP, that is, > 96 hours after intubation. However, as compared to the open group, VAP was observed much later in the closed group (day 7 vs. day 11). Duration of MV, neuro-ICU stay, hospital stay, and mortality did not differ significantly.
Conclusion
In this study, VAP incidences are similar in both the groups. However, neurological patients requiring MV for a short period might benefit from the usage of DHWC with closed suction system as VAP was seen to occur later in this group. Further, a randomized controlled trial with larger sample size is desired to confirm our findings.
Zitieren
APA
Raichurkar, A. K., Ramesh, V., Surve, R. M., Kumari, H. V., & Chakrabarti, D. (2024). Complete Closed-Loop Ventilatory Circuit Delays the Onset of Ventilator-Associated Pneumonia in Mechanically Ventilated Neurological Patients in the ICU: A Single-Center Prospective Preliminary Study. Journal of Neuroanaesthesiology and Critical Care, 11(02), 093-099. https://doi.org/10.1055/s-0044-1787541
Vancouver
Raichurkar AK, Ramesh V, Surve RM, Kumari HV, Chakrabarti D. Complete Closed-Loop Ventilatory Circuit Delays the Onset of Ventilator-Associated Pneumonia in Mechanically Ventilated Neurological Patients in the ICU: A Single-Center Prospective Preliminary Study. Journal of Neuroanaesthesiology and Critical Care. 2024;11(02):093-099. doi:10.1055/s-0044-1787541
BibTeX
@article{Raichurkar2024,
author = {Raichurkar, Archana K. and Ramesh, V.J. and Surve, Rohini M. and Kumari, H.B. Veena and Chakrabarti, Dhritiman},
title = {Complete Closed-Loop Ventilatory Circuit Delays the Onset of Ventilator-Associated Pneumonia in Mechanically Ventilated Neurological Patients in the ICU: A Single-Center Prospective Preliminary Study},
journal = {Journal of Neuroanaesthesiology and Critical Care},
year = {2024},
volume = {11},
number = {02},
pages = {093--099},
doi = {10.1055/s-0044-1787541}
}
EUVIMED