Comparative Geometric Analysis: Patellofemoral Instability with Weight-Bearing versus Non–Weight-Bearing Cone-Beam Computed Tomography Images

N.C. Fornaguera, J. Català, J. Salmeron

Seminars in Musculoskeletal Radiology · 01.06.2024 · 28 (S 01 S 01) · S1-S24

DOI: 10.1055/s-0044-1787469 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Seminars in Musculoskeletal Radiology, erschienen am 01.06.2024. Verfasst von N.C. Fornaguera und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose or Learning Objective: Weight-bearing cone-beam computed tomography (CBCT) facilitates the observation of visible deformities induced by natural weight, such as bone displacement and rotation. This study demonstrates the utility and reliability of geometric analyses conducted on CBCT images with weight-bearing compared with those without weight for patellofemoral instability. Methods or Background: A cohort of 10 patients underwent CBCT both with and without weight-bearing using the Planmed Verity system and the Cefla 5GXL NewTom, respectively. The field of view used was 15 × 12 with a pixel resolution in-plane of 0.2 × 0.2 mm and a slice thickness of 0.2 mm. The analyses focused on evaluating parameters related to knee instability, including the trochlear angle, trochlear depth, trochlear external slope angle, trochlear inclination, knee rotation angle, patellar scale, patellar subluxation, Insall-Salvati modified index, and TA-GT measurement. The measurements were calculated using the Weasis viewer (v.4.2.1). An expert radiologist reviewed the measurements to confirm the correct location. The interclass correlation coefficient (ICC) was evaluated in RStudio (2022.12.0+353) to measure the strength of agreement between the measurements performed by both scanners ( P value < 0.05). Results or Findings: The results showed a high agreement between the measurements of patellar scale (ICC: 0.83), trochlear inclination (ICC: 0.79), trochlear external slope angle (ICC: 0.76), and patellar depth (ICC: 0.76). Furthermore, a moderate agreement was observed for the trochlear angle (ICC: 0.651). However, the Insall-Salvati modified index, patellar subluxation, knee rotation angle, and TA-GT measurements showed poor or negative agreement. The four measurements depend on the positioning and alignment of the joint structures, such as analyzing the displacement of the patella, the relationship between bone structures, the rotation of the knee, and the relationship between the length of the quadriceps tendon and the length of the patella. Introducing weight can alter the positioning of the structures and be contrasted in the measurements. Conclusion: The study demonstrated low consistency in measurements related to the position and alignment of bone structures, and moderate or high consistency in those where they are not. For this reason, weight-bearing CBCT may be considered more useful for the detection of knee instability. Publication History Article published online: 22 May 2024 © 2024. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

Zitieren

APA

Fornaguera, N., Català, J., & Salmeron, J. (2024). Comparative Geometric Analysis: Patellofemoral Instability with Weight-Bearing versus Non–Weight-Bearing Cone-Beam Computed Tomography Images. Seminars in Musculoskeletal Radiology, 28(S 01 S 01), S1-S24. https://doi.org/10.1055/s-0044-1787469

Vancouver

Fornaguera N, Català J, Salmeron J. Comparative Geometric Analysis: Patellofemoral Instability with Weight-Bearing versus Non–Weight-Bearing Cone-Beam Computed Tomography Images. Seminars in Musculoskeletal Radiology. 2024;28(S 01 S 01):S1-S24. doi:10.1055/s-0044-1787469

BibTeX
@article{Fornaguera2024,
  author = {Fornaguera, N.C. and Català, J. and Salmeron, J.},
  title = {Comparative Geometric Analysis: Patellofemoral Instability with Weight-Bearing versus Non–Weight-Bearing Cone-Beam Computed Tomography Images},
  journal = {Seminars in Musculoskeletal Radiology},
  year = {2024},
  volume = {28},
  number = {S 01 S 01},
  pages = {S1--S24},
  doi = {10.1055/s-0044-1787469}
}
Kostenlos starten →