EUVIMEDEUVIMED entdecken
Crossref

Outcomes of 881 Consecutive Coronary Artery Bypass Graft Patients Using Heartstring Device

Kentaro Amano, Yoshiyuki Takami iD, Atsuo Maekawa, Koji Yamana, Kiyotoshi Akita, Kazuki Matsuhashi, Wakana Niwa, Yasushi Takagi

The Thoracic and Cardiovascular Surgeon · 01.04.2025 · 73 (03) · 199-205

DOI: 10.1055/s-0044-1786986 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, erschienen am 01.04.2025. Verfasst von Kentaro Amano und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Fujita Health University School of Medicine, Toyoake, Aichi, Japan. Hauptthemen laut MEDLINE: Coronary Artery Bypass. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Backgrounds One of the strategies to prevent stroke after coronary artery bypass grafting (CABG) may be the use of a device for proximal anastomosis without partial clamp of the ascending aorta.

Methods

We retrospectively investigated early and late outcomes in consecutive 881 patients undergoing isolated CABG using Heartstring for proximal anastomosis from January 2008 to December 2022, to reveal the validity to use it. All patients underwent preoperative imaging workups to evaluate neurovascular atherosclerosis.

Results

The mean age of the patients was 68.9 years, 20% were female and 13% had previous history of stroke. CABG was on-pump beating heart (52.2%) or off-pump (47.8%) with a mean number of distal anastomoses of 3.38 ± 0.93, using 1.62 ± 0.53 Heartstring devices under different aortic manipulations. In-hospital mortality was 2.0% and perioperative stroke rate was 0.9%, none of them died during hospital stay. During the follow-up period of 70 ± 47 months, the overall actuarial survival rates were 86 and 66%, and major adverse cardiac and cerebrovascular events (MACCEs)-free rates were 86 and 70% at 5 and 10 years, respectively. On multivariable analysis, risk factors for late death included male, previous history of stroke, postoperative sternomediastinitis, late new-onset stroke, and MACCEs, but did not include the perioperative stroke.

Conclusion

Low stroke rate, as low as 0.9%, after CABG using Heartstring for proximal anastomosis, although under a variety of aortic manipulations, may contribute to the improved long-term prognosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery BypassRetrospective StudiesFemaleAgedMiddle AgedProportional Hazards ModelsTreatment OutcomeStrokeHumans

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Fujita Health University School of Medicine, Toyoake, Aichi, Japan.

ORCID-Profile: Yoshiyuki Takami

Zitieren

APA

Amano, K., Takami, Y., Maekawa, A., Yamana, K., Akita, K., Matsuhashi, K., Niwa, W., & Takagi, Y. (2025). Outcomes of 881 Consecutive Coronary Artery Bypass Graft Patients Using Heartstring Device. The Thoracic and Cardiovascular Surgeon, 73(03), 199-205. https://doi.org/10.1055/s-0044-1786986

Vancouver

Amano K, Takami Y, Maekawa A, Yamana K, Akita K, Matsuhashi K, et al. Outcomes of 881 Consecutive Coronary Artery Bypass Graft Patients Using Heartstring Device. The Thoracic and Cardiovascular Surgeon. 2025;73(03):199-205. doi:10.1055/s-0044-1786986

BibTeX
@article{Amano2025,
  author = {Amano, Kentaro and Takami, Yoshiyuki and Maekawa, Atsuo and Yamana, Koji and Akita, Kiyotoshi and Matsuhashi, Kazuki and Niwa, Wakana and Takagi, Yasushi},
  title = {Outcomes of 881 Consecutive Coronary Artery Bypass Graft Patients Using Heartstring Device},
  journal = {The Thoracic and Cardiovascular Surgeon},
  year = {2025},
  volume = {73},
  number = {03},
  pages = {199--205},
  doi = {10.1055/s-0044-1786986}
}
Kostenlos starten →