EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Free Flap Monitoring Using Infrared Thermography: An Objective Adjunct to Clinical Monitoring

Priyanka Singla, Pawan Kumar Dixit iD, Prakash Chandra Kala, Deepti Katrolia iD, Shilpi Karmakar iD, Akhilesh Humnekar iD, Apoorva Pratap Singh

Indian Journal of Plastic Surgery · 2024-06 · 57 (03) · 179-183

DOI: 10.1055/s-0044-1786742 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Plastic Surgery, online erschienen am 10.05.2024. Verfasst von Priyanka Singla und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Burns and Plastic Surgery, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Early detection of free flap compromise is critical for salvage of the flap. Various methods of free flap monitoring have been described, but clinical assessment is the standard method for among all. In this study, role of infrared thermography is evaluated for free flap monitoring. Materials and Methods In patients undergoing free flap surgery, monitoring was done using standard clinical parameters and infrared thermography as per our institutional protocol. Mean temperature difference (∆T) between the flap and the surrounding skin was calculated using the temperature readings from the thermal images intra- and postoperatively. The accuracy of infrared thermography in flap monitoring was assessed in comparison to the standard clinical protocol.

Results

Forty-one flaps were included in the analysis, out of which five flaps got compromised. It was observed that the mean temperature difference was higher (mean ∆T 0.20–0.59 vs. 2.38–3.32) when there was a flap compromise, and this temperature difference was evident even before the development of clinical signs. The temperature difference in venous thrombosis (mean ∆T 1.0–2.7) was found to be slightly lower than in arterial insufficiency (mean ∆T 2.1–4.4). For a ∆T cutoff value of 2°C, the thermal camera had a sensitivity of 88.6%, specificity of 98.9%, positive predictive value of 93.9%, and negative predictive value of 97.7%.

Conclusion

Infrared thermography is a valuable and noninvasive objective tool in free flap monitoring, which can detect flap compromise (increasing value of ∆T) even before it becomes clinically evident.

Schlagwörter

Stichwörter der Autor:innen

free flap monitoringfree flapsinfrared thermographythermal imaging

Autor:innen und Institutionen

  • Department of Burns and Plastic Surgery, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.

ORCID-Profile: Pawan Kumar Dixit, Deepti Katrolia, Shilpi Karmakar, Akhilesh Humnekar

Zitieren

APA

Singla, P., Dixit, P. K., Kala, P. C., Katrolia, D., Karmakar, S., Humnekar, A., & Singh, A. P. (2024). Free Flap Monitoring Using Infrared Thermography: An Objective Adjunct to Clinical Monitoring. Indian Journal of Plastic Surgery, 57(03), 179-183. https://doi.org/10.1055/s-0044-1786742

Vancouver

Singla P, Dixit PK, Kala PC, Katrolia D, Karmakar S, Humnekar A, et al. Free Flap Monitoring Using Infrared Thermography: An Objective Adjunct to Clinical Monitoring. Indian Journal of Plastic Surgery. 2024;57(03):179-183. doi:10.1055/s-0044-1786742

BibTeX
@article{Singla2024,
  author = {Singla, Priyanka and Dixit, Pawan Kumar and Kala, Prakash Chandra and Katrolia, Deepti and Karmakar, Shilpi and Humnekar, Akhilesh and Singh, Apoorva Pratap},
  title = {Free Flap Monitoring Using Infrared Thermography: An Objective Adjunct to Clinical Monitoring},
  journal = {Indian Journal of Plastic Surgery},
  year = {2024},
  volume = {57},
  number = {03},
  pages = {179--183},
  doi = {10.1055/s-0044-1786742}
}
Kostenlos starten →