EUVIMEDEUVIMED entdecken
Open Access

Evaluation of Reliability of Dynamic Scapholunate Distance Measured on 4D CT-Acquired Images

Sofie Goeminne iD, Emiel Salaets, Walter Coudyzer, Darshan Shah, Ilse Degreef, Lennart Scheys

Journal of Wrist Surgery · 01.04.2025 · 14 (02) · 177-183

DOI: 10.1055/s-0044-1786161 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Wrist Surgery, erschienen am 01.04.2025. Verfasst von Sofie Goeminne und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: KOOR (University Hospitals Leuven.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

A technique to measure scapholunate distance based on four-dimensional computed tomography (4D CT)-acquired images is presented. Materials and Methods Intra-observer variability was evaluated through a repeated-measures study. A 4D CT of seven patients suspected of scapholunate lesion was performed. Anatomical landmarks were identified on a three-dimensional reconstructed model of the wrist. All 4D CT datasets were evaluated thrice by two observers. Standard deviation of the differences between two measurements, interclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated.

Results

Intra-observer variability for the expert observer (ICC > 0.95) was lower than that of the novice observer (ICC > 0.77) and interobserver variability was low (ICC > 0.85). For the expert observer, measurement error (SEM < 0.13 mm and MDC < 0.36 mm) was smaller than that of the novice observer (SEM < 0.45 mm and MDC < 1.24 mm). Both SEM and MDC values were low, compared to the scan resolution and the absolute value of intervals.

Conclusion

The proposed assessment results in a reproducible and reliable measurement of scapholunate distance.

Schlagwörter

Stichwörter der Autor:innen

4D CTreliabilityscapholunate instability

Autor:innen und Institutionen

  • Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium.
  • Department of Orthopaedic Surgery, AZ Herentals, Herentals, Belgium.
  • Department of Mechanical Engineering, BiOME Lab, Indian Institute of Technology, Bombay, Mumbai, India.

ORCID-Profile: Sofie Goeminne

Förderung

  • KOOR (University Hospitals Leuven

Zitieren

APA

Goeminne, S., Salaets, E., Coudyzer, W., Shah, D., Degreef, I., & Scheys, L. (2025). Evaluation of Reliability of Dynamic Scapholunate Distance Measured on 4D CT-Acquired Images. Journal of Wrist Surgery, 14(02), 177-183. https://doi.org/10.1055/s-0044-1786161

Vancouver

Goeminne S, Salaets E, Coudyzer W, Shah D, Degreef I, Scheys L. Evaluation of Reliability of Dynamic Scapholunate Distance Measured on 4D CT-Acquired Images. Journal of Wrist Surgery. 2025;14(02):177-183. doi:10.1055/s-0044-1786161

BibTeX
@article{Goeminne2025,
  author = {Goeminne, Sofie and Salaets, Emiel and Coudyzer, Walter and Shah, Darshan and Degreef, Ilse and Scheys, Lennart},
  title = {Evaluation of Reliability of Dynamic Scapholunate Distance Measured on 4D CT-Acquired Images},
  journal = {Journal of Wrist Surgery},
  year = {2025},
  volume = {14},
  number = {02},
  pages = {177--183},
  doi = {10.1055/s-0044-1786161}
}
Kostenlos starten →