Bulk-Fill Ormocer versus Methacrylate-Based Resin Composite Restorative Systems: The Effect of Flowable Lining on Two-Year Clinical Performance in Class II Cavities
European Journal of General Dentistry · 01.09.2024 · 13 (03) · 205-215
DOI: 10.1055/s-0044-1785472 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of General Dentistry, erschienen am 01.09.2024. Verfasst von Moustafa Ahmed Elsharkawy und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
The aim of this study was to assess and compare the impact of bulk-fill flowable resin composite liners (BFFL) on the 2-year clinical performance of bulk-fill ormocer (BORC) in comparison to methacrylate-based resin composites (BMRC) in Class II cavities. Materials and Methods Thirty participants, each aged between 18 and 30 years, were included in the study, each presenting four class II cavities. A total of 120 restorations were placed, with participants randomly assigned to one of four restorative systems through a blind drawing: Admira Fusion X-Tra (AFX) alone, AFX after lining with Admira Fusion Xtra-Base (AFB), X-Tra Fill (XF) for complete cavity filling, and XF after lining with Xtra-Base (XB). The universal adhesive system (Futura U bond Voco, Germany) was consistently applied for all restoration techniques using selective enamel etching. A single operator, following the manufacturer's instructions for each material, performed all restorations, and finishing/polishing occurred immediately after placement. Clinical evaluation, based on World Dental Federation (FDI) criteria, was conducted by two blinded examiners at baseline (7 days) and at 6, 12, and 24 months postoperatively.
Results
The chi-squared test was used to compare the four applied restorative systems within each follow-up period, while the marginal homogeneity test was employed to assess changes over time. No statistically significant differences were observed among the four restorative systems at any evaluation period.
Conclusions
After 2 years, the clinical performance of BFFL or complete bulk-fill technique remained similar, regardless of the material composition.
Zitieren
APA
Elsharkawy, M. A., Ibrahim, R. A., Hamama, H. H., & Mahmoud, S. H. (2024). Bulk-Fill Ormocer versus Methacrylate-Based Resin Composite Restorative Systems: The Effect of Flowable Lining on Two-Year Clinical Performance in Class II Cavities. European Journal of General Dentistry, 13(03), 205-215. https://doi.org/10.1055/s-0044-1785472
Vancouver
Elsharkawy MA, Ibrahim RA, Hamama HH, Mahmoud SH. Bulk-Fill Ormocer versus Methacrylate-Based Resin Composite Restorative Systems: The Effect of Flowable Lining on Two-Year Clinical Performance in Class II Cavities. European Journal of General Dentistry. 2024;13(03):205-215. doi:10.1055/s-0044-1785472
BibTeX
@article{Elsharkawy2024,
author = {Elsharkawy, Moustafa Ahmed and Ibrahim, Radwa Ali and Hamama, Hamdi Hosni and Mahmoud, Salah Hasab},
title = {Bulk-Fill Ormocer versus Methacrylate-Based Resin Composite Restorative Systems: The Effect of Flowable Lining on Two-Year Clinical Performance in Class II Cavities},
journal = {European Journal of General Dentistry},
year = {2024},
volume = {13},
number = {03},
pages = {205--215},
doi = {10.1055/s-0044-1785472}
}