EUVIMEDEUVIMED entdecken
Crossref

Aortoesophageal fistula after ingestion of button battery

Luisa Symeou, Ines Ugele, Katharina Tenneberg-Holzer, Melanie Völkl, Domenica Golka, Isolde Schäfer, Christopher Bohr

Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S307

DOI: 10.1055/s-0044-1785035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Luisa Symeou und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Button batteries are an underestimated threat, especially for small children who tend to insert them in their orifices such as the nose, mouth and ears. The flat, round batteries are found in many household items and toys. Ingestion of button batteries can cause them to linger in the throat or oesophagus, in some cases with fatal results. Material and methods Data collection from medical records, imaging and laboratory findings.

Results

A one-year-old child was transferred to our emergency department due to repeated episodes of haematemesis. Initially, no clear cause for the symptoms could be identified. With symptom progression and massive oesophageal bleeding, oesophageal packing and a laparotomy were performed. A subsequent CT thorax/abdomen with contrast showed a button battery in the small bowel and leakage of contrast medium from an aberrant right subclavian artery (arteria lusoria). An attempt to control the haemorrhage by balloon occlusion proved unsuccessful and subsequently led to the death of the child.

Conclusion

There is an urgent need for rapid diagnosis and adequate treatment of button battery ingestion to prevent life-threatening complications. Parents and child carers should be informed about the dangers of button batteries. As a preventive measure, we have developed an information brochure in cooperation with the Bavarian State Ministries for Health and Care, for Family, Labour and Social Affairs and for Science and Art, which draws attention to the dangers and contains recommendations on what to do if a button battery is ingested. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Symeou, L., Ugele, I., Tenneberg-Holzer, K., Völkl, M., Golka, D., Schäfer, I., & Bohr, C. (2024). Aortoesophageal fistula after ingestion of button battery. Laryngo-Rhino-Otologie, 103(S 02 S 02), S307. https://doi.org/10.1055/s-0044-1785035

Vancouver

Symeou L, Ugele I, Tenneberg-Holzer K, Völkl M, Golka D, Schäfer I, et al. Aortoesophageal fistula after ingestion of button battery. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S307. doi:10.1055/s-0044-1785035

BibTeX
@article{Symeou2024,
  author = {Symeou, Luisa and Ugele, Ines and Tenneberg-Holzer, Katharina and Völkl, Melanie and Golka, Domenica and Schäfer, Isolde and Bohr, Christopher},
  title = {Aortoesophageal fistula after ingestion of button battery},
  journal = {Laryngo-Rhino-Otologie},
  year = {2024},
  volume = {103},
  number = {S 02 S 02},
  pages = {S307},
  doi = {10.1055/s-0044-1785035}
}
Kostenlos starten →