Visibility of the tube balloon catheter through the tympanic membrane during balloon eustachian tuboplasty

Benjamin Rahim, Lars-Uwe Scholtz, Christoph Pfeiffer, Alexander Kilgue, Conrad Riemann, Ingo Todt

Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S302

DOI: 10.1055/s-0044-1785014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Benjamin Rahim und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The physiological function of the Eustachian tube is to clean and ventilate the middle ear. Pathological ventilation of the tube can lead to chronic middle ear inflammation, cholesteatoma and chronic dysfunction of the tube itself. In addition to conservative procedures, tympanic drainage and tube dilatation are available as therapeutic options. Balloon catheter-based tube dilatation is a highly effective procedure for the treatment of chronic obstructive tube dysfunction. In terms of application, the procedure is based on standardized anatomical proportions. The aim of this study was to assess the general compatibility of the procedure with the anatomical conditions of the tube by means of a transtympanic visual assessment and to provide recommendations.

Methods

In a prospective study, we assessed the visual assessment of the catheter transtympanaly during different phases of catheter insertion in 10 patients using an auditory canal camera. This was done depending on the position of the catheter insertion in front of the tubal ostium.

Results

Visual transtympanic detection of the catheter tip was found in 30% of cases when positioned in the tubal ostium. When positioned in front of the tubal ostium, there was no transtympanic visual detection.

Conclusion

The positioning of the catheter insertion in the tubal ostium is of central importance for the insertion depth of the catheter. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Rahim, B., Scholtz, L., Pfeiffer, C., Kilgue, A., Riemann, C., & Todt, I. (2024). Visibility of the tube balloon catheter through the tympanic membrane during balloon eustachian tuboplasty. Laryngo-Rhino-Otologie, 103(S 02 S 02), S302. https://doi.org/10.1055/s-0044-1785014

Vancouver

Rahim B, Scholtz L, Pfeiffer C, Kilgue A, Riemann C, Todt I. Visibility of the tube balloon catheter through the tympanic membrane during balloon eustachian tuboplasty. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S302. doi:10.1055/s-0044-1785014

BibTeX
@article{Rahim2024,
  author = {Rahim, Benjamin and Scholtz, Lars-Uwe and Pfeiffer, Christoph and Kilgue, Alexander and Riemann, Conrad and Todt, Ingo},
  title = {Visibility of the tube balloon catheter through the tympanic membrane during balloon eustachian tuboplasty},
  journal = {Laryngo-Rhino-Otologie},
  year = {2024},
  volume = {103},
  number = {S 02 S 02},
  pages = {S302},
  doi = {10.1055/s-0044-1785014}
}
Kostenlos starten →