Perilymph diagnostics – Possibilities of highly sensitive analytic methods for low volume samples
Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S285
DOI: 10.1055/s-0044-1784953 ↗Kurz gefasst
Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Heike Schmitt und 9 weiteren Autor:innen.
Abstract (Originalsprache)
Background
The human inner ear (IE) contains complex sensitive cellular structures. These structures inside the cochlea are vulnerable to e.g. toxic substances, aging, diseases and inflammatory processes. Sensorineural hearing loss can be induced by a wide range of molecular and cellular pathologic changes. These pathologic changes and disease specific biomarkers can be identified in low volume perilymph (PL) samples by performing ultrasensitive analytic methods like proteomics [ 1 ], metabolomics and multiplex protein array (MPA) [ 2 ].
Methods
By liquid biopsy, we are able to collect PL samples with a volume of 0.5-12µl by modified micro glass capillaries during IE surgeries like cochlear implantations. The proteomics and metabolomics approach is based on liquid or gas chromatography coupled to mass spectrometry (MS). A bead based Luminex multiplex technology for MPA enabled the identification of 48 inflammatory proteins like cytokines, chemokines, epithelial and endothelial markers in human PL samples.
Results
The collected PL samples show an average volume of 2µl (14% 4µl). The modified MPA requires only 0.5-2µl sample volume, each MS analysis 2µl. Depending on the sample volume, we could perform 2 or even 3 analytic methods in one PL sample.
Conclusion
Our developed PL sampling method and reducing the required volumes for the applied analytic methods enable a combination of different analytic methods. These multiple analyses enable the identification of hundreds of proteins and metabolites in the obtained low volume PL samples and present a new window of opportunity for understanding the pathologic processes in the IE. Funding information This work was supported by the DFG Cluster of Excellence EXC 2177/1 \"Hearing4all\". Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Schmitt, H., Pich, A., Warnecke, A., Falk, C., Hiller, K., More, T., Blume, C., Durisin, M., Lenarz, T., & Scheper, V. (2024). Perilymph diagnostics – Possibilities of highly sensitive analytic methods for low volume samples. Laryngo-Rhino-Otologie, 103(S 02 S 02), S285. https://doi.org/10.1055/s-0044-1784953
Vancouver
Schmitt H, Pich A, Warnecke A, Falk C, Hiller K, More T, et al. Perilymph diagnostics – Possibilities of highly sensitive analytic methods for low volume samples. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S285. doi:10.1055/s-0044-1784953
BibTeX
@article{Schmitt2024,
author = {Schmitt, Heike and Pich, Andreas and Warnecke, Athanasia and Falk, Christine and Hiller, Karsten and More, Tushar and Blume, Cornelia and Durisin, Martin and Lenarz, Thomas and Scheper, Verena},
title = {Perilymph diagnostics – Possibilities of highly sensitive analytic methods for low volume samples},
journal = {Laryngo-Rhino-Otologie},
year = {2024},
volume = {103},
number = {S 02 S 02},
pages = {S285},
doi = {10.1055/s-0044-1784953}
}
EUVIMED