Performing continuous intraoperative impedance telemetry measurements during Cochlear Implantation
Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S273
DOI: 10.1055/s-0044-1784909 ↗Kurz gefasst
Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Magdalena Weiss Nora und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Repeated impedance measurements during cochlear implant electrode insertion may enable objective feedback on whether the electrode is positioned inside the perilymph or outside the inner ear.
Method
We present a method in which impedances can be measured in real-time during cochlear implantation. For successful recordings, a standardized procedure is mandatory. In this contribution, we comprehensively illustrate the system setup and procedure of performing intraoperative measurements during CI surgery.
Results
Using this measurement protocol, we performed measurements with 40 patients. Impedances were measured at the end of the second phase of a biphasic stimulation pulse in monopolar mode. Phase duration was 27 µs, stimulation amplitude was 150 µA when measuring at the stimulating contact, and 600 µA when measuring at non-stimulating contacts. All used electrodes contain 12 stimulation contacts that can be used for stimulation, but also for voltage measurements. Therefore, in total 144 single measurements were performed for retrieving a 12 x 12 voltage matrix. Every 2s the whole matrix measurements was repeated. We found a good visual alignment between the surgeon"s annotations, the video, and the drop of impedances.
Conclusion
We hypothesize that the method may be used as an objective insertion marker and feedback mechanism for monitoring the status of electrode insertion. The audio signal is considered an additional helpful approach to guide the insertion speed that was chosen to be approximately 10 s per electrode contact in this protocol (corresponding to approximately 4 mm/s). Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Nora, M. W., Dazert, S., Hans, S., Schmutzhard, J., Wimmer, W., Dierker, A., & Wollenberg, B. (2024). Performing continuous intraoperative impedance telemetry measurements during Cochlear Implantation. Laryngo-Rhino-Otologie, 103(S 02 S 02), S273. https://doi.org/10.1055/s-0044-1784909
Vancouver
Nora MW, Dazert S, Hans S, Schmutzhard J, Wimmer W, Dierker A, et al. Performing continuous intraoperative impedance telemetry measurements during Cochlear Implantation. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S273. doi:10.1055/s-0044-1784909
BibTeX
@article{Nora2024,
author = {Nora, Magdalena Weiss and Dazert, Stefan and Hans, Stefan and Schmutzhard, Joachim and Wimmer, Wilhelm and Dierker, Angelika and Wollenberg, Barbara},
title = {Performing continuous intraoperative impedance telemetry measurements during Cochlear Implantation},
journal = {Laryngo-Rhino-Otologie},
year = {2024},
volume = {103},
number = {S 02 S 02},
pages = {S273},
doi = {10.1055/s-0044-1784909}
}
EUVIMED