Individualized cochlear implantation – first experience with a new 34 mm electrode for patients with very long cochleae
Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S269
DOI: 10.1055/s-0044-1784895 ↗Kurz gefasst
Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Andrea Schreier und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
Introduction
In cochlear implantation choosing the ideal electrode for each patient is crucial. It has been shown that there is a broad variation of the morphology of the cochlea, which can be estimated by the cochlear duct length (CDL). From our patients a relevant proportion has a relatively long CDL and therefore needs a longer electrode for a better electrical cochlear coverage. To optimize tonotopic mapping, a 34 mm long electrode array was designed by MED-EL. This study describes the first experience with the new FLEX34, including surgical experience, patients" characteristics and outcomes. Material and Methods So far, seventeen patients have received the new FLEX34. Patient characteristics and audiometry results were collected and CDL, angular insertion depth (AID) and electrical cochlear coverage (CC) were calculated with OTOPLAN. Statistical analysis was conducted by computing the mean and standard deviation (SD).
Results
All patients had a full insertion. The mean CDL was 38.7 mm (SD+/- 2,1 mm), the mean CC was 74,1% (SD+/- 4,1%) and the mean AID was 667,1° (SD+/- 36,5°). Postoperative vertigo was observed in one patient with simultaneous endolymphatic sac surgery. One patient had a postoperative emphysema, which regressed after conservative treatment. No other postoperative complications were observed (incomplete insertion, tip-foldover, kinking, vestibular symptoms). Speech understanding showed mean 65% monosyllables at 65 dB one year postoperatively (SD+/- 20%). Conclusion/Discussion The FLEX34 is a logical step towards a more personalized cochlea implantation addressing the known variation of the CDL. When complying to landmark-based surgery it is an easy to handle, seemingly less traumatic electrode with good postoperative speech understanding. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Schreier, A., Molenda, C., Draut, S., Hempel, J., Volgger, V., Polterauer, D., Merz, L., & Müller, J. (2024). Individualized cochlear implantation – first experience with a new 34 mm electrode for patients with very long cochleae. Laryngo-Rhino-Otologie, 103(S 02 S 02), S269. https://doi.org/10.1055/s-0044-1784895
Vancouver
Schreier A, Molenda C, Draut S, Hempel J, Volgger V, Polterauer D, et al. Individualized cochlear implantation – first experience with a new 34 mm electrode for patients with very long cochleae. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S269. doi:10.1055/s-0044-1784895
BibTeX
@article{Schreier2024,
author = {Schreier, Andrea and Molenda, Carmen and Draut, Sarah and Hempel, John-Martin and Volgger, Veronika and Polterauer, Daniel and Merz, Lena and Müller, Joachim},
title = {Individualized cochlear implantation – first experience with a new 34 mm electrode for patients with very long cochleae},
journal = {Laryngo-Rhino-Otologie},
year = {2024},
volume = {103},
number = {S 02 S 02},
pages = {S269},
doi = {10.1055/s-0044-1784895}
}