Postoperative dizziness after cochlear implant surgery: Can it be caused by air?

Till Fabian Jakob, Antje Aschendorff, Susan Arndt, Ann-Kathrin Rauch, Manuel Christoph Ketterer

Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S257

DOI: 10.1055/s-0044-1784851 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Till Fabian Jakob und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The occurrence of dizziness after CI surgery varies depending on the study and is one of the most common complications. A distinction is made between acute and chronic vertigo. Various mechanisms of vertigo development are discussed, such as direct trauma caused by electrode insertion, acute serous labyrinthitis due to cochleostomy, foreign body reaction with labyrinthitis, endolymphatic hydrops and electrical stimulation by the implant. Material/Methods We examined 67 patients postoperatively with the question of dizziness. 52 underwent postoperative cone-beam CT (CBCT) to check the position of the electrode and 15 underwent flat panel CT (FPCT). The 52 CBCTs images were analysed for possible air trapping in the labyrinth. It was not possible to make a statement on this for the FPCTs.

Results

Of the 67 patients, 5 complained of dizziness postoperatively, 2 of whom also had spontaneous nystagmus. Of the 5 patients, 4 underwent postoperative CBCT and 1 underwent FPCT. In one patient, air trapping was found in the vestibule, parts of the lateral semicircular canal and the basal cochlear. In 3 other patients, there were suspicious changes in the vestibule due to air trapping. In the other 48 CBCTs, there was no evidence of air in the vestibule.

Discussion

In addition to the causes of postoperative vertigo mentioned above, it can also be caused by air in the vestibule. The pneumolabyrinth after CI surgery has only been described sporadically. Air is most likely to enter through the cochleostomy or the round window. In the postoperative radiological electrode placement check, attention should not only be paid to the correct intracochlear electrode position, but the vestibule should also be assessed. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Jakob, T. F., Aschendorff, A., Arndt, S., Rauch, A., & Ketterer, M. C. (2024). Postoperative dizziness after cochlear implant surgery: Can it be caused by air?. Laryngo-Rhino-Otologie, 103(S 02 S 02), S257. https://doi.org/10.1055/s-0044-1784851

Vancouver

Jakob TF, Aschendorff A, Arndt S, Rauch A, Ketterer MC. Postoperative dizziness after cochlear implant surgery: Can it be caused by air?. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S257. doi:10.1055/s-0044-1784851

BibTeX
@article{Jakob2024,
  author = {Jakob, Till Fabian and Aschendorff, Antje and Arndt, Susan and Rauch, Ann-Kathrin and Ketterer, Manuel Christoph},
  title = {Postoperative dizziness after cochlear implant surgery: Can it be caused by air?},
  journal = {Laryngo-Rhino-Otologie},
  year = {2024},
  volume = {103},
  number = {S 02 S 02},
  pages = {S257},
  doi = {10.1055/s-0044-1784851}
}
Kostenlos starten →