Influence of cochlear anatomy, insertion technique and cochlear trauma on tinnitus burden – a long term follow up

Friederike Everad, Antje Aschendorff, Susan Arndt, Ann-Kathrin Rauch, Rainer Beck, Manuel Christoph Ketterer

Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S253

DOI: 10.1055/s-0044-1784835 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Friederike Everad und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The aim of this prospective study was to investigate long-term tinnitus intensity and burden after CI implantation and to compare it regarding cochlear anatomy, insertion technique and scalar dislocation.

Methods

65 patients were examined preoperatively, 2 days, 4 weeks, 12 and 24 months after CI implantation. Pre- and postoperative imaging (computed tomography or digital volume tomography) was used to determine cochlear morphology, scalar position, insertion depth and dislocation. Tinnitus intensity was measured by the visual analogue scale whereas tinnitus burden was assessed by the Tinnitus Questionnaire.

Results

Tinnitus burden was greatly reduced by CI treatment over time, while tinnitus intensity remained constant. However, if the speech processor was worn, tinnitus severity was significantly lower. Dislocations occurred in 6% of cases, with round window insertions showing no increased risk of dislocation or tinnitus exacerbation. Extended round window insertions, however, showed dislocations more frequently. Nevertheless, they did not lead to higher tinnitus burden or severity during the long-term follow up. Cochlear morphology did not influence dislocation or tinnitus burden.

Conclusion

CI implantation can successfully reduce the severity and burden of tinnitus in the long-term. Round window insertion is preferable to cochleostomy and extended round window insertion, as the risk of dislocation is significantly lower. However, dislocation, scalar position, insertion technique or cochlear morphology showed no influence on the tinnitus severity in the long-term follow up. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Everad, F., Aschendorff, A., Arndt, S., Rauch, A., Beck, R., & Ketterer, M. C. (2024). Influence of cochlear anatomy, insertion technique and cochlear trauma on tinnitus burden – a long term follow up. Laryngo-Rhino-Otologie, 103(S 02 S 02), S253. https://doi.org/10.1055/s-0044-1784835

Vancouver

Everad F, Aschendorff A, Arndt S, Rauch A, Beck R, Ketterer MC. Influence of cochlear anatomy, insertion technique and cochlear trauma on tinnitus burden – a long term follow up. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S253. doi:10.1055/s-0044-1784835

BibTeX
@article{Everad2024,
  author = {Everad, Friederike and Aschendorff, Antje and Arndt, Susan and Rauch, Ann-Kathrin and Beck, Rainer and Ketterer, Manuel Christoph},
  title = {Influence of cochlear anatomy, insertion technique and cochlear trauma on tinnitus burden – a long term follow up},
  journal = {Laryngo-Rhino-Otologie},
  year = {2024},
  volume = {103},
  number = {S 02 S 02},
  pages = {S253},
  doi = {10.1055/s-0044-1784835}
}
Kostenlos starten →