EUVIMEDEUVIMED entdecken
Crossref

Investigations on directional hearing and speech intelligibility in the case of unilateral fitting with an active middle ear implant or an active bone conduction implant

Christoph Müller, Hannes Seidler, Janina Kuch, Anna Tsypina, Thomas Zahnert, Susen Lailach

Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S246

DOI: 10.1055/s-0044-1784808 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Christoph Müller und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

In 20 patients unilaterally fitted with Vibrant Soundbridge (VSB) and 10 patients fitted with Bonebridge (BB) (both from MED-EL, Austria) (implantation at least 6 months ago, contralateral ear with at most mild hearing loss (PTA4 0.05) in terms of patient age (VSB 41.6±12.9 yrs (standard deviation); BB 42.6±16.5 yrs), PTA4 of bone conduction in the PTA (VSB 24.4±8.3 dB; BB 20.8 dB±4.2 dB), OLSA (VSB -7.8dB±3.6dB; BB -7.0 dB±5.5dB) and SI (VSB 83.3%±14.6%; BB 75.0%±18.4%). Implantation was 3.0 yrs±1.1 yr (VSB) and 7.6 yrs±1.9 yr (BB) behind (p 0.05). Lateral sound presentations above 60° were increasingly perceived in the direction contralateral to the sound source in both groups (p>0.05).

Conclusion

When comparing the sound localization ability, the measurements to date show no significant differences between VSB and BB users. Further measurement data must be collected for a final judgment. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Müller, C., Seidler, H., Kuch, J., Tsypina, A., Zahnert, T., & Lailach, S. (2024). Investigations on directional hearing and speech intelligibility in the case of unilateral fitting with an active middle ear implant or an active bone conduction implant. Laryngo-Rhino-Otologie, 103(S 02 S 02), S246. https://doi.org/10.1055/s-0044-1784808

Vancouver

Müller C, Seidler H, Kuch J, Tsypina A, Zahnert T, Lailach S. Investigations on directional hearing and speech intelligibility in the case of unilateral fitting with an active middle ear implant or an active bone conduction implant. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S246. doi:10.1055/s-0044-1784808

BibTeX
@article{Mller2024,
  author = {Müller, Christoph and Seidler, Hannes and Kuch, Janina and Tsypina, Anna and Zahnert, Thomas and Lailach, Susen},
  title = {Investigations on directional hearing and speech intelligibility in the case of unilateral fitting with an active middle ear implant or an active bone conduction implant},
  journal = {Laryngo-Rhino-Otologie},
  year = {2024},
  volume = {103},
  number = {S 02 S 02},
  pages = {S246},
  doi = {10.1055/s-0044-1784808}
}
Kostenlos starten →