Optimizing the diagnostic performance of preoperative ultrasound examination of parotid gland tumors through qualitative assessment of contrast-enhanced sonography
Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S174-S175
DOI: 10.1055/s-0044-1784555 ↗Kurz gefasst
Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Katharina Margherita Wakonig und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Ultrasound (US) is considered the imaging method of choice in the diagnosis of parotid gland tumors (PGT). Although PGT are mostly benign, malignant transformation is possible even in benign tumors. For this reason, surgical removal is preferred. Since the surgical treatment strategy differs in terms of radicality between benign and malignant PGT, an optimal preoperative assessment of malignancy is important. The aim of this prospective study was to improve the diagnostic performance of PGT-US through qualitative analysis of multiparametric US (mpUS).
Methods
93 PGT (67 benign, 26 malignant) were preoperatively examined using a standardized US-examination protocol (B-mode-US, shear wave elastography (SWE), contrast enhancing US (CEUS)). The images were qualitatively evaluated by an experienced US examiner regarding malignancy (evaluating borders, homogeneity and microvasculariztion), and the diagnostic performance of each method was evaluated. The histopathological result served as the reference.
Results
B-mode-US achieved the highest specificity and positive predictive value (PPV) with 97% and 86%, respectively, while sensitivity (46%) and negative predictive value (NPV, 82%) were lower compared to CEUS (sensitivity 77%, NPV 89%, specificity 73%, PPV 53%). SWE did not perform superior to the other modalities.
Discussion
The qualitative mpUS-analysis shows that malignant PGT can be reliably detected using CEUS compared to conventional ultrasound, and if microvascularization is not suspicious, malignancy can be excluded with high probability. If there are uncertainties regarding malignancy in the B-mode image, CEUS can provide additional information and allow for better preoperative planning. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Wakonig, K. M., Lerchbaumer, M. H., Arens, P., Fischer, T., Olze, H., & Dommerich, S. (2024). Optimizing the diagnostic performance of preoperative ultrasound examination of parotid gland tumors through qualitative assessment of contrast-enhanced sonography. Laryngo-Rhino-Otologie, 103(S 02 S 02), S174-S175. https://doi.org/10.1055/s-0044-1784555
Vancouver
Wakonig KM, Lerchbaumer MH, Arens P, Fischer T, Olze H, Dommerich S. Optimizing the diagnostic performance of preoperative ultrasound examination of parotid gland tumors through qualitative assessment of contrast-enhanced sonography. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S174-S175. doi:10.1055/s-0044-1784555
BibTeX
@article{Wakonig2024,
author = {Wakonig, Katharina Margherita and Lerchbaumer, Markus Herbert and Arens, Philipp and Fischer, Thomas and Olze, Heidi and Dommerich, Steffen},
title = {Optimizing the diagnostic performance of preoperative ultrasound examination of parotid gland tumors through qualitative assessment of contrast-enhanced sonography},
journal = {Laryngo-Rhino-Otologie},
year = {2024},
volume = {103},
number = {S 02 S 02},
pages = {S174--S175},
doi = {10.1055/s-0044-1784555}
}
EUVIMED