EUVIMEDEUVIMED entdecken
Crossref

The Impact of Cholangioscope Diameter Variation on Cholangioscopy Outcomes: A Retrospective Comparative Study

C. Robles-Medranda, J. Baquerizo-Burgos, M. Puga-Tejada, J. Alcivar-Vasquez, R. Del Valle, H. Alvarado-Escobar, M. Egas-Izquierdo, D. Cunto, M. Arevalo-Mora, H. Pitanga-Lukashok

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S472

DOI: 10.1055/s-0044-1783897 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von C. Robles-Medranda und 9 weiteren Autor:innen. Die Arbeit nennt 2 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Digital single-operator cholangioscopy (DSOC) stands as an invaluable diagnostic and therapeutic instrument, offering direct visualization of the biliary ducts. The use of cholangioscopes with higher diameter may raise concerns regarding patient discomfort and safety. Smaller diameter cholangioscopes could offer enhanced maneuverability and decreased risk of adverse events, improving procedural success rates. The aim of this study is to compare the impact of cholangioscope diameter variation on cholangioscopy outcomes, with a focus on procedure success rates.

Methods

A retrospective, comparative study performed in patients who underwent either diagnostic or therapeutic DSOC from January 2021 to August 2023 were retrospectively collected. A P 20mm were performed with the 11.1F (61%) (P=.01), with a total removal of stones of 64.5%. Technical success was higher in the 9.3F (97.0% vs 90.6%), clinical success was higher in the 11.1F (96.2% vs 94.0%). All cases performed with the 7F cholangioscope were diagnostic, 7/8 procedures with 7F allow a complete evaluation of the intrahepatic ducts, 1/8 had a complete post-surgical CBD stenosis, and achieved a 100% technical and clinical success rate. [ 1 ] [ 2 ]

Conclusions

Cholangioscope diameter should be tailored to the specific diagnostic or therapeutic needs. While the 9.3F cholangioscope is more suitable for diagnostic procedures and has a higher technical success rate, the 11.1F is preferable for therapeutic interventions, particularly for larger biliary stones where higher caliber lithotripter is required. The 7F cholangioscope presents an effective alternative for complete intrahepatic duct evaluations. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Robles-Medranda, C., Baquerizo-Burgos, J., Puga-Tejada, M., Alcivar-Vasquez, J., Valle, R. D., Alvarado-Escobar, H., Egas-Izquierdo, M., Cunto, D., Arevalo-Mora, M., & Pitanga-Lukashok, H. (2024). The Impact of Cholangioscope Diameter Variation on Cholangioscopy Outcomes: A Retrospective Comparative Study. Endoscopy, 56(S 02 S 02), S472. https://doi.org/10.1055/s-0044-1783897

Vancouver

Robles-Medranda C, Baquerizo-Burgos J, Puga-Tejada M, Alcivar-Vasquez J, Valle RD, Alvarado-Escobar H, et al. The Impact of Cholangioscope Diameter Variation on Cholangioscopy Outcomes: A Retrospective Comparative Study. Endoscopy. 2024;56(S 02 S 02):S472. doi:10.1055/s-0044-1783897

BibTeX
@article{RoblesMedranda2024,
  author = {Robles-Medranda, C. and Baquerizo-Burgos, J. and Puga-Tejada, M. and Alcivar-Vasquez, J. and Valle, R. Del and Alvarado-Escobar, H. and Egas-Izquierdo, M. and Cunto, D. and Arevalo-Mora, M. and Pitanga-Lukashok, H.},
  title = {The Impact of Cholangioscope Diameter Variation on Cholangioscopy Outcomes: A Retrospective Comparative Study},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S472},
  doi = {10.1055/s-0044-1783897}
}
Kostenlos starten →