Combining a Computer Aided Detection system (CADe) and G-EYE balloon for adenoma detection in a FIT-based organized colorectal cancer screening program: preliminary results of a randomized controlled trial
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S456
DOI: 10.1055/s-0044-1783851 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von S. Rocchetto und 18 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Recent evidence shows that Computer Aided Detection (CADe) systems and mucosal-exposure devices might exert a synergic effect in adenoma detection during colonoscopy. We aimed at evaluating if the combination of CADe and GEYE balloon increases the adenoma detection in a fecal immunochemical test (FIT)-based colorectal cancer screening program.
Methods
50-74 years old FIT-positive subjects were randomized to undergo either CADe or CADe+GEYE colonoscopy, by accredited endoscopists. Main outcomes measures were the rate of “high-risk” subjects according to ESGE criteria ( > 5 low risk adenoma, at least one adenoma with high-risk features, any serrated polyp≥10 mm or with dysplasia), and the adenoma detection rate (ADR). According to previous studies, we planned to include 600 subjects.
Results
Between May and October 2023, 188 subjects (61.8±6.55 years old; 97 men) were collected. Of them 91 and 97 underwent CADe colonoscopy and CADe+GEYE colonoscopy, respectively. No significant differences in patients' features, cleansing level, insertion, overall withdrawal, and inspection time were observed across the two study groups. The rate of “high-risk” subjects after colonoscopy was 21.9% (95% CI: 14.0-31.8%) and 21.6% (95% CI: 13.9-31.2%) in those receiving CADe and CADe+GEYE colonoscopy, respectively. The ADR was 59.3% (95% CI: 48.5-69.5%) and 58.8% (95% CI: 48.3-68.7%) in CADe and CADe+GEYE colonoscopy respectively.
Conclusions
Our preliminary data suggest that adding GEYE to CADe does not significantly increase the adenoma detection. These conclusions must be interpreted with caution since full data are awaited. However, we can hypothesize that a “ceiling effect” due to the high detection rate of lesions with CADe have marginalized the impact of mucosal-exposure device. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Rocchetto, S., Segatta, F., Piagnani, A., Paggi, S., Bina, N., Paolo, D. D., Scardino, G., Terreni, N., Mandelli, G., Buscarini, E., Romeo, S., Alicante, S., Buda, A., Rizzotto, E. R., Mitri, R. D., Hassan, C., Repici, A., Rondonotti, E., & Radaelli, F. (2024). Combining a Computer Aided Detection system (CADe) and G-EYE balloon for adenoma detection in a FIT-based organized colorectal cancer screening program: preliminary results of a randomized controlled trial. Endoscopy, 56(S 02 S 02), S456. https://doi.org/10.1055/s-0044-1783851
Vancouver
Rocchetto S, Segatta F, Piagnani A, Paggi S, Bina N, Paolo DD, et al. Combining a Computer Aided Detection system (CADe) and G-EYE balloon for adenoma detection in a FIT-based organized colorectal cancer screening program: preliminary results of a randomized controlled trial. Endoscopy. 2024;56(S 02 S 02):S456. doi:10.1055/s-0044-1783851
BibTeX
@article{Rocchetto2024,
author = {Rocchetto, S. and Segatta, F. and Piagnani, A. and Paggi, S. and Bina, N. and Paolo, D. Di and Scardino, G. and Terreni, N. and Mandelli, G. and Buscarini, E. and Romeo, S. and Alicante, S. and Buda, A. and Rizzotto, E. Rosa and Mitri, R. Di and Hassan, C. and Repici, A. and Rondonotti, E. and Radaelli, F.},
title = {Combining a Computer Aided Detection system (CADe) and G-EYE balloon for adenoma detection in a FIT-based organized colorectal cancer screening program: preliminary results of a randomized controlled trial},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S456},
doi = {10.1055/s-0044-1783851}
}
EUVIMED