Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von F. De Vincentis und 3 weiteren Autor:innen. Die Arbeit nennt 1 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Delayed bleeding is a well known complication in 2-3% of resective endoscopic procedures. The aim of this study was to assess the efficacy and safety of Purastat when used to prevent delayed bleeding in endoscopic submucosal dissection (ESD).

Methods

Profilactic Purastat was used after esophageal, gastric or rectal ESD for lesions of 15 – 70 mm in patients over 18 years of age scheduled for an elective procedure.

Results

20 gastric, 15 rectal, 1 colonic and 1 esophageal ESD were performed in 37 patients (19 F) between march 2022 and september 2023. 32% of patients were on antiaggregant therapy, while 13% discontinued anticoagulation treatment before procedure. The mean lesion size was 25.8 mm (15-70 mm). Intraprocedural bleeding and perforation occured in 38% and 2.7% of patients, respectively, and managed endoscopically. The delayed bleeding rate was 0%.

Conclusions

In this small, prospective single center series no patient undergoing ESD experienced delayed bleeding after the profilactic use of a self-assembling peptide. Acknowledging that the use of Purastat adds cost to the procedure, it could represent an advantage in the overall cost-effectiveness. Larger sample size and randomized controlled studies are needed to confirm these preliminary data. [ 1 ] [ 2 ] Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Vincentis, F. D., Brancaccio, M. L., Salzetta, A., & Mussetto, A. (2024). Profilactic self-assembling peptide (PuraStat) is very effective in preventing delayed bleeding in patients undergoing endoscopic submucosal dissection: a prospective single center experience. Endoscopy, 56(S 02 S 02), S438-S439. https://doi.org/10.1055/s-0044-1783801

Vancouver

Vincentis FD, Brancaccio ML, Salzetta A, Mussetto A. Profilactic self-assembling peptide (PuraStat) is very effective in preventing delayed bleeding in patients undergoing endoscopic submucosal dissection: a prospective single center experience. Endoscopy. 2024;56(S 02 S 02):S438-S439. doi:10.1055/s-0044-1783801

BibTeX
@article{Vincentis2024,
  author = {Vincentis, F. De and Brancaccio, M. L. and Salzetta, A. and Mussetto, A.},
  title = {Profilactic self-assembling peptide (PuraStat) is very effective in preventing delayed bleeding in patients undergoing endoscopic submucosal dissection: a prospective single center experience},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S438--S439},
  doi = {10.1055/s-0044-1783801}
}
Kostenlos starten →