Aims
Capsule endoscopy (CE) is commonly used as the initial exam in situations of suspected mid-gastrointestinal bleeding, after normal upper and lower endoscopy. Although the assessment of the small bowel is its primary focus, detection of upstream/downstream of vascular lesions may also be clinically significant. This study aimed to develop and test a Convolutional Neural Network (CNN)-based model for panendoscopic automatic detection of vascular lesions during CE. [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [ 9 ]
Methods
A multicentric retrospective study was conducted, based on 1188 CE exams. We used a total of 152312 frames, from seven types of CE devices, of which 14942 had vascular lesions (angiectasia, varices) after triple validation. Data was divided in training/validation (90%) and test (10%) groups, in an exam-split design. We conducted a 5-fold cross validation, during training/validation set. This process was iterated five times. Main outcomes were sensitivity, specificity, accuracy, area under the conventional receiver operating characteristic curve (AUC-ROC) and the precision-recall curve (AUC-PR), from the training/validation phase.
Results
Mean sensitivity and specificity were 87.5% (IC95% 81.5 – 93.6%) and 99.5% (IC95% 99.3 – 99.7%), respectively. Mean accuracy was 98.4% (IC95% 97.7 – 99.1%). Mean AUC-ROC value was 0.987 (IC95% 0.980 – 0.995), while AUC-PR value was 0.998 (IC95% 0.997 – 1.000).
Conclusions
This is the first proof-of concept AI deep learning model developed for panendoscopic automatic detection of vascular lesions during CE. The high diagnostic performance of this CNN in multibrand devices addresses an important issue of technological interoperability, allowing it to be replicated in multiple technological settings. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Cardoso, P. M., Mascarenhas, M., Afonso, J. P., Ribeiro, T., Miguel, M., Francisco, M., Patrícia, A., Hélder, C., João, P. F., & Guilherme, M. (2024). Deep Learning and Capsule Endoscopy: Automatic Panendoscopic Detection of Vascular Lesions. Endoscopy, 56(S 02 S 02), S419-S420. https://doi.org/10.1055/s-0044-1783752
Vancouver
Cardoso PM, Mascarenhas M, Afonso JP, Ribeiro T, Miguel M, Francisco M, et al. Deep Learning and Capsule Endoscopy: Automatic Panendoscopic Detection of Vascular Lesions. Endoscopy. 2024;56(S 02 S 02):S419-S420. doi:10.1055/s-0044-1783752
BibTeX
@article{Cardoso2024,
author = {Cardoso, P. Marílio and Mascarenhas, M. and Afonso, J. P. and Ribeiro, T. and Miguel, M. and Francisco, M. and Patrícia, A. and Hélder, C. and João, P. F. and Guilherme, M.},
title = {Deep Learning and Capsule Endoscopy: Automatic Panendoscopic Detection of Vascular Lesions},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S419--S420},
doi = {10.1055/s-0044-1783752}
}
EUVIMED