Enhancing Colonic Endoscopic Therapeutic Procedures: First Multi-Centre European Retrospective Study on the Performance of a Double Balloon Overtube Device
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S416
DOI: 10.1055/s-0044-1783743 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von H. Rehman und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Complex endoscopic therapeutic procedures, such as Endoscopic Mucosal Resection (EMR) and Endoscopic Mucosal Dissection (ESD) pose challenges in patients with loopy bowels and those with colostomies due to difficulties in establishing stable endoscopic access to lesion sites. This study investigates the safety and efficacy of a double balloon overtube device (DiLumen, Lumendi LLC) (Figure 1) in facilitating these procedures by providing improved access, stability, and traction.
Methods
A retrospective study was conducted on 42 consecutive patients undergoing overtube-assisted complex endoscopic therapeutic procedures across two centres in Barcelona, Spain and Nottingham, United Kingdom between November 2019-October 2023. Outcomes assessed included sedation type utilized, reason for overtube use, device insertion time, lesion location, colonoscope reinsertion time through device, procedural time, type of intervention, specimen size, final histology, and any associated adverse events/complications.
Results
The median age of enrolees was 73 years with a Charlson comorbidity index score of 3. (31) patients were from Nottingham, United Kingdom and (11) patients were from Barcelona, Spain. In 15 (37.5%) patients had failed prior therapeutic procedures and were referred for overtube assisted endoscopic therapy. In 95.3% of cases (N=40) DiLumen was found to be useful in overcoming difficult access, preventing air leakage in 3 patients with prior colostomies, and in completing the intervention. In two patients the device was not useful; one couldn’t tolerate the device and in the other the shorter length overtube couldn’t reach the caecum. There were no complications or device related adverse events in the cases. The median scope/device insertion time to caecum was 9 minutes and a median of 90 seconds to reinsert the endoscope to the lesion regardless of lesion location. Mean procedure time was 65 min with a median specimen size of 37,5 mm (26-58). Table 1 illustrates outcomes of some other parameters in this study.
Conclusions
This is the first multi-centre case series study in Europe evaluating the performance of a double balloon overtube platform device. It is also the first to report use of the device through a colostomy in several patients as well as use of the device as a conduit for powered endoscopic resection. In our experience, the device was used safely and effectively and appears to reduce procedure time, especially in cases requiring repeated endoscope reinsertion during therapy while improving the speed and success rate of more laborious procedures like ESD providing traction via suture loops during dissection. This study supports the integration of this device in clinical practice for improved outcomes in those with difficult colonic anatomy and complex polyps. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Rehman, H., Uchima, H., Sansone, S., Muñoz-González, R., Rojo, E., Budihal, S., & Adolfo, P. B. (2024). Enhancing Colonic Endoscopic Therapeutic Procedures: First Multi-Centre European Retrospective Study on the Performance of a Double Balloon Overtube Device. Endoscopy, 56(S 02 S 02), S416. https://doi.org/10.1055/s-0044-1783743
Vancouver
Rehman H, Uchima H, Sansone S, Muñoz-González R, Rojo E, Budihal S, et al. Enhancing Colonic Endoscopic Therapeutic Procedures: First Multi-Centre European Retrospective Study on the Performance of a Double Balloon Overtube Device. Endoscopy. 2024;56(S 02 S 02):S416. doi:10.1055/s-0044-1783743
BibTeX
@article{Rehman2024,
author = {Rehman, H. and Uchima, H. and Sansone, S. and Muñoz-González, R. and Rojo, E. and Budihal, S. and Adolfo, P. B.},
title = {Enhancing Colonic Endoscopic Therapeutic Procedures: First Multi-Centre European Retrospective Study on the Performance of a Double Balloon Overtube Device},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S416},
doi = {10.1055/s-0044-1783743}
}
EUVIMED