Endoscopic ultrasound characteristics of solid component as a determinant for plastic versus metal stent drainage in walled-off pancreatic necrosis with significant debris: A pilot study
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S364
DOI: 10.1055/s-0044-1783594 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von B. R. Patra und 8 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Endoscopic ultrasonography (EUS) guided drainage for walled-off pancreatic necrosis (WOPN) with significant solid debris with plastic stents vs metal stent is conflicting. We aimed to study EUS characteristics of solid debris to determine the choice of stent, need for endoscopic necrosectomy and compared effectiveness of drainage with this strategy.
Methods
A total of 31 symptomatic WOPN patients with solid debris>30% were included in the study. All underwent EUS for characterisation of the solid debris into two groups according to distribution pattern (evenly distributed particulate vs irregular shaped reticulate), echogenecity (hypo-echoic vs hyper-echoic with or without shadowing), uniformity (homogenous vs heterogenous) & completeness of distant wall (present vs absent). Group A included those with former group of characteristics (minimum three out of four) and represented softer debris while Group B included later characteristics (either irregular shaped reticulate pattern alone or two out of the other three) and suggested tough debris. Group A underwent drainage with two double pigtail plastic stents while group B underwent drainage with either bi-flanged fully covered self-expanding metallic stent or lumen apposing metal stent. Primary outcome was treatment success defined as symptom relief with resolution of WOPN at 3 months. Secondary outcome was need for repeat procedures or direct endoscopic necrosectomy. Treatment failure was considered if there was any change in modality of drainage or death.
Results
Technical success was seen in 100% patients in both groups. Clinical success with symptoms resolution was seen in 85.71% (12/14) in group A and 94.11% (16/17) in group B, P-0.43. Radiological resolution was seen in 92.8% (13/14) in group A and 88.2% (15/17) in group B, P-0.66. Treatment failure was seen in 2/14 (14%) patients in group A with both requiring upgradation to metal stent and 1/17 (5.8%) in group B requiring surgical necrosectomy, P-0.43. Direct endoscopic necrosectomy (DEN) was needed in 13/17 patients (76.4%) in group B (mean session 1.33) and 2/14 (14%) in group A (mean session 1), P-0.005. Three patients (17.6%) in group B required lavage by nasocystic drain along with DEN. There was no procedure related major adverse events or death.
Conclusions
EUS characteristic of solid component in WOPN with significant debris determines the need for future necrosectomy and hence the choice of stent for drainage. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Patra, B. R., Ansari, A. A., Harindranath, S., Vaidya, A., Garg, L., Patwardhan, N., Jain, G., Mane, P., & Shukla, A. (2024). Endoscopic ultrasound characteristics of solid component as a determinant for plastic versus metal stent drainage in walled-off pancreatic necrosis with significant debris: A pilot study. Endoscopy, 56(S 02 S 02), S364. https://doi.org/10.1055/s-0044-1783594
Vancouver
Patra BR, Ansari AA, Harindranath S, Vaidya A, Garg L, Patwardhan N, et al. Endoscopic ultrasound characteristics of solid component as a determinant for plastic versus metal stent drainage in walled-off pancreatic necrosis with significant debris: A pilot study. Endoscopy. 2024;56(S 02 S 02):S364. doi:10.1055/s-0044-1783594
BibTeX
@article{Patra2024,
author = {Patra, B. R. and Ansari, A. A. and Harindranath, S. and Vaidya, A. and Garg, L. and Patwardhan, N. and Jain, G. and Mane, P. and Shukla, A.},
title = {Endoscopic ultrasound characteristics of solid component as a determinant for plastic versus metal stent drainage in walled-off pancreatic necrosis with significant debris: A pilot study},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S364},
doi = {10.1055/s-0044-1783594}
}
EUVIMED