It’s all about time: validation of an Asian model for colorectal ESD
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S350
DOI: 10.1055/s-0044-1783556 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von D. Verhoeven und 5 weiteren Autor:innen. Die Arbeit nennt 3 Literaturangaben.
Abstract (Originalsprache)
Aims
Overcoming logistical challenges for the routine implementation of endoscopic submucosal dissection (ESD) at Western endoscopy centers requires accurate prediction of procedure times. The Zhongshan CR-ESD model, designed to predict difficulty of ESD procedures, has recently been updated. We evaluated the performance of the updated Zhongshan CR-ESD model in a Western ESD cohort.
Methods
Records of consecutive patients who underwent single, non-hybrid colorectal ESDs before 2020 at three Dutch tertiary hospitals were retrospectively reviewed. The updated Zhongshan CR-ESD model included the four predictors of the previous model (tumor size, lesion circumference, anatomical location, morphology), along with preceding biopsy and narrow-band imaging international colorectal endoscopic (NICE) category to classify ESD difficulty into four groups: easy, moderate, difficult, and very difficult. The predicted outcome was ESD completion within 60 minutes. As exploratory analysis, we also evaluated the predictive performance of the model when changing the value of the dichotomization cut-off. [ 1 ] [ 2 ] [ 3 ]
Results
A total of 435 colorectal ESDs were analyzed (92% en bloc resections, mean duration 139 minutes, mean tumor size 39mm). Overall, 25% of ESDs were classified as easy, 36% as intermediate, 30% as difficult, and 9% as very difficult. In the original Eastern discovery cohort, the percentages were 42%, 35%, 20%, and 3%, respectively. Our cohort demonstrated a lower rate of ESDs completed within 60 minutes (14%) compared to the original cohort (54%). Completion rates within 60 minutes per category were: 27% for easy, 13% for intermediate, 9% for difficult, and 5% for very difficult (75%, 49%, 26%, and 8% in the original discovery cohort, respectively). The area under the curve (AUC) of the updated Zhongshan CR-ESD model for colorectal ESD duration 40 vs.≤40; i.e. same cut-off for experts/non-experts used in the original discovery cohort) and endoscopy center yielded comparable AUCs (range 0.622-0.664). When increasing the dichotomization cut-off for the outcome, we found a proportional increase in both the AUC and the proportion of ESDs completed within that time. When using a dichotomization cut-off of 120, 180, 240, and 300 minutes, the AUCs were 0.716, 0.746, 0.814, and 0.857, and the proportions of ESDs completed within the cut-off time were 48%, 75%, 90%, and 95%, respectively.
Conclusions
In a Western setting, the updated Zhongshan CR-ESD model has a relatively lower performance in predicting ESD completion 2-3 hours) of colorectal ESDs at Western endoscopy centers. Adjusting the model, e.g. by including other relevant factors like ESD experience, may enhance the predictive performance. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Verhoeven, D., Moons, L. G., Koch, A., Hardwick, J., Boonstra, J., & Dang, H. (2024). It’s all about time: validation of an Asian model for colorectal ESD. Endoscopy, 56(S 02 S 02), S350. https://doi.org/10.1055/s-0044-1783556
Vancouver
Verhoeven D, Moons LG, Koch A, Hardwick J, Boonstra J, Dang H. It’s all about time: validation of an Asian model for colorectal ESD. Endoscopy. 2024;56(S 02 S 02):S350. doi:10.1055/s-0044-1783556
BibTeX
@article{Verhoeven2024,
author = {Verhoeven, D. and Moons, L.M. G. and Koch, A. and Hardwick, J. and Boonstra, J. and Dang, H.},
title = {It’s all about time: validation of an Asian model for colorectal ESD},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S350},
doi = {10.1055/s-0044-1783556}
}
EUVIMED