EUVIMEDEUVIMED entdecken
Crossref

Reality Augmented Glasses Improves Ergonomics in Gastrointestinal Endoscopy

S. Kim, H. S. Choi, H. J. Jeon, E. S. Kim, B. Keum, Y. T. Jeen, H. J. Chun

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S350

DOI: 10.1055/s-0044-1783555 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von S. Kim und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Endoscopists are at increased risk of musculoskeletal injuries (MSI). Poor endoscopic posture is known to cause MSI. In this study, we systematically evaluated the ergonomic benefits of medical augmented reality glasses (ARG) in gastrointestinal endoscopy.

Methods

Screening gastroscopies were performed with and without ARG. The subjective experience was evaluated using a questionnaire-based NASA-Task Load Index (NASA-TLX). Biomechanical loads during endoscopy were captured using electromyography (EMG) sensors and motion tracking sensors. Perceived discomfort, muscle activity and body position were compared between ARG wearing group and non- ARG group.

Results

Five endoscopists performed total of 200 upper gastrointestinal endoscopies; 100 procedures in ARG group and 100 procedures in non-ARG group. Mean NASA-TLX scores of the participants were lower when ARG was used compared to those with conventional monitor. ARG wearing group exhibited improvements in physical demand, effort, and frustration scores compared to non ARG group. Muscle activation was significantly lower in ARG group compared to non ARG group in sternocleidomastoid and trapezius muscles. IMU analysis showed a significant reduction in the proportion of high risk positions of the neck and torso in the ARG group.

Conclusions

ARG was effective in improving the ergonomics of the examiner by correcting the bad posture of neck and torso during endoscopy. It reduces muscle fatigue and significantly corrects high risk posture that causes pain during endoscopy. The use of ARG in gastrointestinal endoscopy is expected to improve ergonomics for endoscopists. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Kim, S., Choi, H. S., Jeon, H. J., Kim, E. S., Keum, B., Jeen, Y. T., & Chun, H. J. (2024). Reality Augmented Glasses Improves Ergonomics in Gastrointestinal Endoscopy. Endoscopy, 56(S 02 S 02), S350. https://doi.org/10.1055/s-0044-1783555

Vancouver

Kim S, Choi HS, Jeon HJ, Kim ES, Keum B, Jeen YT, et al. Reality Augmented Glasses Improves Ergonomics in Gastrointestinal Endoscopy. Endoscopy. 2024;56(S 02 S 02):S350. doi:10.1055/s-0044-1783555

BibTeX
@article{Kim2024,
  author = {Kim, S. and Choi, H. S. and Jeon, H. J. and Kim, E. S. and Keum, B. and Jeen, Y. T. and Chun, H. J.},
  title = {Reality Augmented Glasses Improves Ergonomics in Gastrointestinal Endoscopy},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S350},
  doi = {10.1055/s-0044-1783555}
}
Kostenlos starten →