Patency testing prior to Video Capsule Endoscopy: An Irish Experience
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S331-S332
DOI: 10.1055/s-0044-1783504 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von C. Costigan und 11 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.
Abstract (Originalsprache)
Aims
Capsule retention, a rare but significant complication of Video Capsule Endoscopy (VCE), occurs in 1-2% of patients [ 1 ] [ 2 ], depending on indication [ 3 ] [ 4 ]. Patency Capsules (PC) are dissolvable radio-opaque capsules which assess GI tract patency & effectively identify patients with retention risk [ 5 ]. ESGE recommends PC prior to VCE in certain conditions [ 6 ]. Our aim was to assess PC protocols in use & the factors affecting outcomes across Ireland.
Methods
Procedural data: VCE & PC Indication, Local protocols & Success rates were collected retrospectively from 5 tertiary centres. Demographics & Radiological results were collected from the electronic patient record and analysed using appropriate statistical analysis.
Results
364 procedures were reviewed. 212 (58%) were female, mean age=48 years. VCE indications: Suspected IBD 115 (34%), IBD assessment 82 (24%), IDA/GI Bleeding 62(20%), Low Risk Symptoms 33 (10%), Abnormal Imaging 15 (4%). PC indications: GI Surgery 68 (20%), Known Crohn’s 72 (21%), Obstructive Symptoms 52 (15%), Stenosis on Imaging 33 (10%), NSAIDs 30 (9%). 81 Patients (23%) did not have valid PC indication per ESGE guidelines. Overall, 77 patients (21%) were fasted. 184 (51%) Passed (Mean age=49, 53% female). Another 32 (10%) proceeded to CE despite ‘failure’. Age, Gender & Fasting were not predictors of PC passage (p=0.4126, p=0.2032, p=0.4441). Pass rates were similar in all centres (X 2 = 7.3.647, p=0.66733). Analysis of pass rate by VCE indication (X 2 =13.354, p=0.639) and PC indication (X 2 =7.86, p=0.2482) also failed to show significance.
Conclusions
There are similar completion rates for PC across Ireland, and for Age, Gender and PC/VCE indication. This is surprising as we know transit time slows with age. Fasting does not appear necessary for PC. Similar completion rates for patients with a valid ESGE PC indications and without, likely represents a high false negative rate. We recommend the introduction of 3D imaging to accurately assess location & increase PC pass rate. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Costigan, C., O'Hara, F., O´sullivan, A. M., Osmerova, I., Carroll, A., Gibbons, E., Goulding, C., Hussey, M., Holleran, G., Hall, B., Buckley, M., & McNamara, D. (2024). Patency testing prior to Video Capsule Endoscopy: An Irish Experience. Endoscopy, 56(S 02 S 02), S331-S332. https://doi.org/10.1055/s-0044-1783504
Vancouver
Costigan C, O'Hara F, O´sullivan AM, Osmerova I, Carroll A, Gibbons E, et al. Patency testing prior to Video Capsule Endoscopy: An Irish Experience. Endoscopy. 2024;56(S 02 S 02):S331-S332. doi:10.1055/s-0044-1783504
BibTeX
@article{Costigan2024,
author = {Costigan, C. and O'Hara, F. and O´sullivan, A. M. and Osmerova, I. and Carroll, A. and Gibbons, E. and Goulding, C. and Hussey, M. and Holleran, G. and Hall, B. and Buckley, M. and McNamara, D.},
title = {Patency testing prior to Video Capsule Endoscopy: An Irish Experience},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S331--S332},
doi = {10.1055/s-0044-1783504}
}
EUVIMED