Completeness of screening colonoscopy reports: cross sectional study in a national quality assurance program
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S307
DOI: 10.1055/s-0044-1783434 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von J. Zessner-Spitzenberg und 7 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Documentation of Key Performance Measures (KPM) recommended by the European Society for Gastrointestinal Endoscopy on written colonoscopy reports is paramount to establish quality assurance in screening programs. Whether KPM for screening colonoscopy can be extracted from written colonoscopy reports within a quality assurance program has not been investigated yet.
Methods
We extracted KPM from written colonoscopy reports collected from a data audit between 2020-2021. Whether there was an association of the presence of KPM with the endoscopy service’s specialty or setting (internal medicine practice, surgery practice, hospital), Adenoma Detection Rate or annual colonoscopy volume was assessed using a logistic regression model.
Results
319 reports were analyzed. Except for the documentation of cecal intubation, no specialty or setting reached completeness in documentation of all KPM. While internal medicine private practice endoscopists had lower report quality in the documentation of adequate polypectomy technique (OR 0.23, 95% CI 0.0734 – 0.7225, p=0.0118), reports from private practice surgeons were incomplete in terms of bowel preparation documentation (OR 0.26, 0.0966 – 0.6821, p=0.0064). The Adenoma Detection Rate or annual colonoscopy volume was not associated with higher report completeness.
Conclusions
In this analysis of written colonoscopy reports from a quality assurance program, we observed overall high missingness of KPM elements in screening colonoscopy. We did not observe a particular pattern of high missingness in a single specialty or setting, hence, report quality improvement initiatives should target all colonoscopy providers. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Zessner-Spitzenberg, J., Waldmann, E., Rockenbauer, L. M., Daniela, P., Demschik, A., Majcher, B., Trauner, M., & Ferlitsch, M. (2024). Completeness of screening colonoscopy reports: cross sectional study in a national quality assurance program. Endoscopy, 56(S 02 S 02), S307. https://doi.org/10.1055/s-0044-1783434
Vancouver
Zessner-Spitzenberg J, Waldmann E, Rockenbauer LM, Daniela P, Demschik A, Majcher B, et al. Completeness of screening colonoscopy reports: cross sectional study in a national quality assurance program. Endoscopy. 2024;56(S 02 S 02):S307. doi:10.1055/s-0044-1783434
BibTeX
@article{ZessnerSpitzenberg2024,
author = {Zessner-Spitzenberg, J. and Waldmann, E. and Rockenbauer, L. M. and Daniela, P. and Demschik, A. and Majcher, B. and Trauner, M. and Ferlitsch, M.},
title = {Completeness of screening colonoscopy reports: cross sectional study in a national quality assurance program},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S307},
doi = {10.1055/s-0044-1783434}
}
EUVIMED