Case Report: Removal of duodenal over-the-scope clip via duodenoscope
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S293-S294
DOI: 10.1055/s-0044-1783393 ↗Kurz gefasst
Fallbericht in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von C. Triller. Die Arbeit nennt 2 Literaturangaben.
Abstract (Originalsprache)
Aims
To show a successful over-the-scope clip removal via duodenoscope Methods Clinical case report Results Over-the-scope clips can be used for endoscopic closure of wall defects in the upper and lower GI tract, for stent fixation and primary hemostasis. In upper GI bleeding, the use of over-the-scope clip is superior to through-the scope (TTS) Clips [ 1 ]. While over-the-scope clips can be left in place in most cases, complications like intestinal stenosis require a removal. As underlined in clinical cohorts, the remOVE DC Cutter is a safe tool applying to gastroscopes or colonoscopes [ 2 ]. In contrast, the use of duodenoscopes in this setting is uncommon. In our case 2 over-the-scope clips were used for bleeding duodenal ulcers. One misplaced over-the-scope clip was successfully removed by using the remOVE DC Cutter via duodenoscope. The Case: A 75y old male patient presented with signs of upper GI bleeding. Index endoscopy revealed kissing ulcers in the duodenum. For primary hemostasis, two mini over-the-scope clips were placed. Two days after, the patient showed signs of cholestasis. Initially, a CT scan was performed to rule out a liver abscess or other reasons for cholestasis. CT scan showed one over-the-scope clip in papillary position with compression of the common bile duct. An immediate endoscopic control with standard gastroscope could not clearly visualize the papilla, with two over-the-scope clips in the duodenum. Changing to a duodenoscope could localize the distant over-the-scope clip misplaced around the papilla – due to initial straightening of the duodenum when deploying the over-the-scope clip. Using a distant cap+dual channel gastroscope, a grasping forceps and the remOVE DC cutter were inserted. In the second part of the duodenum – in an unstable position- the integer over-the-scope clip ring could not be visualized and contacted by the DC cutter. Therefore we changed to a duodenoscope to improve stability – now the elevator allowed to contact the over-the-scope clip in the upper and lower part with sufficient pressure. The over-the-scope clip ring was disintegrated into two parts, and removed using the grasping forceps. The use of bipolar direct current did not lead to significant mucosal lesions. Bile flow started immediately after clip removal, so we abandoned further cannulation of the common bile duct. Further clinical course was uneventful without signs of bleeding, the patient recovered and was discharged.
Conclusions
Removing over-the-scope clip in the second part of the duodenum can be performed safely using a duodenoscope. The elevator allows contacting the ring with sufficient pressure. Using bipolar direct current via the remOVE DC cutter does not lead to significant mucosal lesions. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Triller, C. (2024). Case Report: Removal of duodenal over-the-scope clip via duodenoscope. Endoscopy, 56(S 02 S 02), S293-S294. https://doi.org/10.1055/s-0044-1783393
Vancouver
Triller C. Case Report: Removal of duodenal over-the-scope clip via duodenoscope. Endoscopy. 2024;56(S 02 S 02):S293-S294. doi:10.1055/s-0044-1783393
BibTeX
@article{Triller2024,
author = {Triller, C.},
title = {Case Report: Removal of duodenal over-the-scope clip via duodenoscope},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S293--S294},
doi = {10.1055/s-0044-1783393}
}
EUVIMED