Abstract (Originalsprache)

Aims

Endoscopic local treatments including endobiliary radiofrequency ablation (EB-RFA) have got noticed for palliative management of cholangiocarcinoma. However, safety concerns have emerged, and clinical benefits have not yet been accurately demonstrated. We have newly developed a dilation balloon-equipped cylindrical laser light diffuser for local endoscopic treatment of cholangiocarcinoma. We focused on the comparison of the safety and efficacy of biliary endoscopic balloon-based laser treatment (B-EBLT) and EB-RFA in normal bile duct swine model.

Methods

Ten mini pigs were randomly allocated into B-EBLT and EB-RFA groups. All animals underwent endoscopic retrograde cholangiography. And B-EBLT (active length; 5 mm, electrical power; 10 ~>7 W, irradiation time; 10 sec) and EB-RFA (electrode length; 22 mm, electrical power; 7 W, ablation time; 80 sec) were performed in each 5 animals in both groups. Follow-up cholangiogram was done in all animals right after the procedures. And the bile ducts were extracted from all animals for pathologic analysis 24 hours later.

Results

No bile duct perforation or hemobilia occurred in all animals of both groups. Ablation depth of biliary EBLT was about half that of EB-RFA (mean, 2.2 vs. 4.8 mm). And the ablation length of biliary EBLT was approximately 1.5 times that of active length in laser diffuser (mean, 8.4 mm) and the ablation length was like the electrode length in case of EB-RFA (mean, 18.2 mm).

Conclusions

Biliary EBLT and EB-RFA showed acceptable safety profile in normal swine bile duct. And biliary EBLT showed a thinner tissue coagulation depth & more uniform necrosis than EB-RFA. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Jeong, S., Lim, J. H., Lee, J., & Lee, D. H. (2024). Safety and efficacy of biliary endoscopic balloon-based laser treatment vs. endobiliary radiofrequency ablation in swine models. Endoscopy, 56(S 02 S 02), S243. https://doi.org/10.1055/s-0044-1783253

Vancouver

Jeong S, Lim JH, Lee J, Lee DH. Safety and efficacy of biliary endoscopic balloon-based laser treatment vs. endobiliary radiofrequency ablation in swine models. Endoscopy. 2024;56(S 02 S 02):S243. doi:10.1055/s-0044-1783253

BibTeX
@article{Jeong2024,
  author = {Jeong, S. and Lim, J. H. and Lee, J. and Lee, D. H.},
  title = {Safety and efficacy of biliary endoscopic balloon-based laser treatment vs. endobiliary radiofrequency ablation in swine models},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S243},
  doi = {10.1055/s-0044-1783253}
}
Kostenlos starten →