Safety and efficacy of biliary endoscopic balloon-based laser treatment vs. endobiliary radiofrequency ablation in swine models
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S243
DOI: 10.1055/s-0044-1783253 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von S. Jeong und 3 weiteren Autor:innen. Die Arbeit nennt 2 Literaturangaben.
Abstract (Originalsprache)
Aims
Endoscopic local treatments including endobiliary radiofrequency ablation (EB-RFA) have got noticed for palliative management of cholangiocarcinoma. However, safety concerns have emerged, and clinical benefits have not yet been accurately demonstrated. We have newly developed a dilation balloon-equipped cylindrical laser light diffuser for local endoscopic treatment of cholangiocarcinoma. We focused on the comparison of the safety and efficacy of biliary endoscopic balloon-based laser treatment (B-EBLT) and EB-RFA in normal bile duct swine model.
Methods
Ten mini pigs were randomly allocated into B-EBLT and EB-RFA groups. All animals underwent endoscopic retrograde cholangiography. And B-EBLT (active length; 5 mm, electrical power; 10 ~>7 W, irradiation time; 10 sec) and EB-RFA (electrode length; 22 mm, electrical power; 7 W, ablation time; 80 sec) were performed in each 5 animals in both groups. Follow-up cholangiogram was done in all animals right after the procedures. And the bile ducts were extracted from all animals for pathologic analysis 24 hours later.
Results
No bile duct perforation or hemobilia occurred in all animals of both groups. Ablation depth of biliary EBLT was about half that of EB-RFA (mean, 2.2 vs. 4.8 mm). And the ablation length of biliary EBLT was approximately 1.5 times that of active length in laser diffuser (mean, 8.4 mm) and the ablation length was like the electrode length in case of EB-RFA (mean, 18.2 mm).
Conclusions
Biliary EBLT and EB-RFA showed acceptable safety profile in normal swine bile duct. And biliary EBLT showed a thinner tissue coagulation depth & more uniform necrosis than EB-RFA. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Jeong, S., Lim, J. H., Lee, J., & Lee, D. H. (2024). Safety and efficacy of biliary endoscopic balloon-based laser treatment vs. endobiliary radiofrequency ablation in swine models. Endoscopy, 56(S 02 S 02), S243. https://doi.org/10.1055/s-0044-1783253
Vancouver
Jeong S, Lim JH, Lee J, Lee DH. Safety and efficacy of biliary endoscopic balloon-based laser treatment vs. endobiliary radiofrequency ablation in swine models. Endoscopy. 2024;56(S 02 S 02):S243. doi:10.1055/s-0044-1783253
BibTeX
@article{Jeong2024,
author = {Jeong, S. and Lim, J. H. and Lee, J. and Lee, D. H.},
title = {Safety and efficacy of biliary endoscopic balloon-based laser treatment vs. endobiliary radiofrequency ablation in swine models},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S243},
doi = {10.1055/s-0044-1783253}
}
EUVIMED